Final Operations - Smeg Oven Instructions For The User

Hide thumbs Also See for Oven:
Table of Contents

Advertisement

15.FINAL OPERATIONS

After replacing the nozzles, reposition the flame-spreader crowns, the burner caps and the racks.
Following adjustment to a gas other than the preset one, replace the gas setting label fixed to the
appliance with the one corresponding to the new gas. This label is inside the packing containing the
nozzles.
15.1 Regulation of the hob burner minimum level for natural gas
Light the burner and turn it to the minimum position
and turn the adjustment screw at the side of the tap rod until the correct minimum
flame is achieved. Refit the knob and verify that the burner flame is stable (when
turning the knob rapidly from the maximum to the minimum position the flame
must not go out). Repeat the operation on all the gas taps.
For models with valves, keep the knob at minimum level for about 1 minute to keep the flame lit and to
activate the safety device.
15.2 Regulation of the hob burner minimum level for LPG
In order to adjust the minimum with LPG, the screw at the side of the tap rod must be turned clockwise
all the way. The bypass diameters for each individual burner are shown in paragraph "14.2 Burner and
nozzle characteristics table". Once the regulation has been completed, restore the seal on the by-
passes using paint or similar materials.
15.3 Mounting the rear top skirtboard
• Loosen nuts B.
• Position the skirt above the top, taking care to align
pins C with holes D.
• Secure the skirt to the top by tightening screws A.
15.4 Positioning and levelling the appliance (on some models only)
After making the electrical and gas connections, level the appliance on the floor by means of its four
adjustable feet. For good cooking results, the appliance must be properly levelled. Depending on the
model you have purchased, the foot height adjustment range may vary from 70 to 95 mm and from 110
to 160 mm. These heights refer to the distance between the highest point of the foot (fixed part) and the
lowest point (movable part which rests on the floor).
52
Instructions for the installer
. Extract the gas tap knob

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents