Instructions for the installer

4. FINAL OPERATIONS

After changing the nozzles, put the pan stands, the burner caps and flame diffuser rings back in place.
After adjusting for use of a gas other than the gas used for testing the appliance, replace the gas setting
label on the appliance with the label for the new gas. The label is supplied in the bag with the nozzles.
4.1 Regulation of the hob burner minimum level for natural gas
Light the burner and turn it to the minimum position
. Extract the gas tap knob
and turn the adjustment screw at the side of the tap rod until the correct minimum
flame is achieved.
Refit the knob and verify that the burner flame is stable (turning the knob rapidly
from the maximum to the minimum position the flame must not go out). Repeat
the operation on all the gas taps.
For models with valves, keep the knob at minimum level for about 1 minute to keep the flame lit and to
activate the safety device.
4.2 Regulation of the hob burner minimum level for ULPG
In order to adjust the minimum with ULPG, the screw at the side of the tap rod must be turned clockwise
all the way. The bypass diameters for each individual burner are shown in paragraph "3.2 Burner and
nozzle characteristics table". Once the regulation has been completed, restore the seal on the by-
passes using paint or similar materials.