For operation on 380-415V3N~: use an H05V2V2-F type five-core
cable (5 x 1.5 mm
For operation on 380-415V2N~: use an H05V2V2-F type four-core
cable (4 x 1.5 mm
For operation on 220-240V~: use an H05V2V2-F type three-core
cable (3 x 2.5 mm
The end to be connected to the appliance must have an earth wire
(yellow-green) at least 20 mm longer than the others.
THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR DAMAGE TO PERSONS OR
THINGS CAUSED BY NON-OBSERVANCE OF THE ABOVE PRESCRIPTIONS.

13.2 Room ventilation

The room containing the appliance should have a permanent air supply in accordance with the
standards in force. The room where the appliance is installed must have enough air flow as required for
the regular combustion of gas and by the necessary air exchange of the same room. The air vents,
protected by grills, must be suitably dimensioned in compliance with the current regulations and
positioned so that no part of them is obstructed.
13.3 Extraction of the combustion products
The combustion products must be extracted by means of hoods connected to a natural draught chimney
whose efficiency is certain or via forced extraction. An efficient extraction system requires precision
planning by a specialist qualified in this area and must comply with the positions and distances indicated
by the applicable standards. When the job is complete, the installer must issue a certificate of conformity.
13.4 Connection to gas
Installation of the UNI-CIG 7140 compliant rubber hose must be carried out so that
the hose length is no greater than 1.5 metres. Make sure that the hose does not
come into contact with moving parts and is not squashed. The inside diameter of the hose must be 8 mm
for LIQUID
GAS and 13 mm for NATURAL GAS and CITY GAS.
Verify that all the following conditions are met:
• the hose is fixed to the hose connection with safety clamps;
• no part of the hose is in contact with hot walls (max. 50°C);
• the hose is not under traction or tension and has no tight curves or twists;
• the hose is not in contact with sharp objects or sharp corners;
• if the hose is not perfectly airtight and leaks gas, do not try to repair it: replace it with a new hose;
• verify that the hose is not past its expiry date (serigraphed on the hose itself).
CONNECTION USING RUBBER HOSES COMPLYING WITH THE CURRENT REGULATIONS IS
ONLY PERMITTED IF THE HOSE CAN BE INSPECTED ALONG ITS ENTIRE LENGTH.