WSS100 - WST100 DV
Cleaning the containers
WARNING!
Before proceeding with these operations, turn off the
vacuum cleaner and remove the plug from the power
socket.
Chip Basket
•
Clean the container after each emptying (see "Emptying
the chip basket" paragraph).
•
Check that the holes are free of dirt; clean them if
necessary.
Liquid container
1
Float ball and support plate
2
Chip basket
3
Container closing band
4
Drain valve
•
Empty the liquid container (see "Emptying the containers"
paragraph).
•
Open the liquid container closing band (3).
•
Lift the motor head.
•
Remove the float, its support (1) and the chip basket (2)
•
Wash the container with water to remove deposits.
•
Open the valve (4) to empty the container.
•
Close the drain valve (4).
•
Place the float drain, its support and the chip basket back
into position.
•
Lock the motor head by using the liquid container closing
band (3).
09/2009
Figure 9
Cleaning or replacement of the safety
filters
1
Safety filters
2
Separator
3
Filter cover
•
Open the container closing band (3 fig 9).
•
Lift off the motor head
•
Remove the filter cover (3) and the separator (2) after
removing the screws.
•
Clean the filters (1) with water or replace them if
necessary.
•
Install the filter cover (3), the separator (2) and the filters
(1) by replacing the fixing screws.
•
Reinstall the motor head and close the container with the
appropriate closing band.
Seal inspection
1
Vacuum hose
2
Sight level hose
•
Hoses check
Make sure that the suction connecting hose (1) and the
sight level hose (2) are in a good condition and correctly
fixed.
If the hose is damaged or broken, it must be replaced.
1
Gasket
2
Liquid container
3
Motor head
Replace the seal (1) between the container (2) and the
motor head (3) if it is torn, cut, etc.
8
Figure 10
Figure 11
Figure 12