7.
Tighten the rigging clamps securely to the structure.
8.
Verify that there are no combustible materials or surfaces to be illuminated within 1 meter of the fixture,
and that there are no flammable materials nearby.

Connecting the serial link

T i p s f o r b u i l d i n g a s e r i a l l i n k
1.
Use shielded twisted-pair cable designed for RS-485 devices. Standard microphone cable cannot
transmit control data reliably over long runs; use only cable designed for RS-485 applications. 24 AWG
cable is suitable for runs up to 300 meters (1000 ft). Heavier gauge cable and/or an amplifier is recom-
mended for longer runs.
2.
Never use a "Y" connector to split the link. To split the serial link into branches use a splitter such
as the Martin 4-Channel Opto-Isolated RS-485 Splitter/Amplifier.
3.
Do not overload the link. Up to 32 devices may be connected on a serial link.
4.
Terminate the link by installing a termination plug in the output socket of the last fixture on the link.
The termination plug, which is simply a male XLR connector with a 120 ohm, 0.25 watt resistor sol-
dered between pins 2 and 3, "soaks up" the control signal so it does not reflect back down the link and
cause interference. If a splitter is used, terminate each branch of the link.
C o n n e c t i n g f i x t u r e s
The MAC 600/E has locking 3-pin data input and output sockets that can be configured for use with either DMX or Martin
Protocol controllers. The default pin-out is configured to the DMX-512 standard, i.e., pin 1 to shield, pin 2 to signal (-) and
pin 3 to signal (+).
3-pin to 3-pin
Phase-Reversing
Cable
Connections
Male
Female
1
2
3
P/N 11820006
1.
Connect the controller's data output to the MAC 600/E's data input. For a
DMX controller with 5-pin output: use a cable with 5-pin male and 3-pin female connectors such as
P/N 11820005. Pins 4 and 5 are not used.
DMX controller with 3-pin output: use a cable with 3-pin male and female connectors such as the one
supplied.
Martin RS-485 Protocol controller: use a phase-reversing cable, such as P/N 11820006, with 3-pin
male and female connectors or reconfigure the XLR output.
2.
Continue the link: connect the output of the fixture closest to the controller to the input of the next fix-
ture. Use a phase-reversing cable when connecting a DMX-standard (pin 3 +) device to a Martin-stan-
dard (pin 3 -) device.
Insert a male 120 Ω XLR termination plug in the output of the last fixture on the link.
3.
3-pin to 5-pin
Phase-Reversing
Cable
Connections
Male
Female
1
1
1
2
2
2
3
3
3
4
5
P/N 11820002
User Manual
5-pin to 3-pin
5-pin to 3-pin
Phase-Reversing
Cable
Connections
Connections
Male
Female
Male
1
1
1
2
2
2
3
3
3
4
4
5
5
P/N 11820003
P/N 11820005
3-pin to 5-pin
Straight
Straight
Cable
Cable
Connections
Female
Male
1
1
2
2
3
3
P/N 11820004
Female
1
2
3
4
5
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents