M A C 6 0 0 E ( e l e c t r o n i c b a l l a s t )
The electronic ballast works at any voltage between 100 and 250 volts, and at any frequency between 50 and 60 Hz.
1.
Disconnect the fixture from AC power. Remove the top covers.
2.
Tap the transformer for the local supply voltage as shown below.
3.
Verify that the primary fuse, which is located near the power switch, is correct for the voltage setting.
Use a T 6.3 A fuse when the transformer is set at 200, 210, 220, 230, or 240 V. Use a T 10 A fuse
when it is set at 100, 110, or 120 V.
4.
Replace the top covers before applying power.