[OPTION] menu
[BLANK]
When [BLANK] is activated, output is 12 V. If the
setting is released, output is 0 V.
[RS-232C COMMAND LINK]
Receives commands (
device and outputs 12 V.
Input
z
[POWER ON/OFF]
[POWER ON/OFF]
If the trigger input signal from the external device is
changed from 0 V to 12 V, the projector power will be
switched on. And if it is changed from 12 V to 0 V, the
power will be switched off.
[BLANK]
If the trigger input signal from the external device is
changed from 0 V to 12 V, the screen will go blank. And
if it is changed from 12 V to 0 V, the [BLANK] setting
will be released.
3)
Press the ▲▼◄► buttons to move the
cursor to [DELAY TIME]
4)
Press the ◄► buttons to set the delay
time for the trigger output signal
The delay time can be set to 2, 4, 6, 8, 10, 20, and
z
30 seconds.
It is possible to delay the trigger output signal (12 V)
z
by the amount of time set. (Only available if Trigger
OUTPUT item is selected.)
E.g.) Select [SELECT 4:3 ASPECT] of the trigger output
function and set the delay time to 10 seconds.
Set the [ASPECT] in the [POSITION] menu to [4:3],
and 12V is output from the trigger port after 10
seconds.
Note
You should not use trigger terminal output as the power
z
source for other devices.
The projector will not accept trigger input while preparing
z
to project after the power has been switched on and
while preparing to shutdown after projection. Input trigger
signals after projection starts or after entering standby
mode.
12 V cannot be output from the trigger terminal when the
z
projector is in standby mode.
76 - ENGLISH
page 98) from external
[BLANK]

[SLEEP]

Set the time for the power to be automatically turned
off.
Switch settings
[OFF]
Inactive
[60MIN.]
Turn power off after 60 minutes
[90MIN.]
Turn power off after 90 minutes
[120MIN.]
Turn power off after 120 minutes
[150MIN.]
Turn power off after 150 minutes
[180MIN.]
Turn power off after 180 minutes
[210MIN.]
Turn power off after 210 minutes
[240MIN.]
Turn power off after 240 minutes
Note
At the set period of time has elapsed the power is turned
z
off automatically (the power indicator is illuminated red).
3 minutes before turn-off, the number of minutes
z
remaining will be displayed in the lower right corner.
If [SLEEP] mode is set to [OFF] mode before the
z
specified time has elapsed the settings are erased.

[HIGH ALTITUDE MODE]

Set to [ON] when using at locations between 1400 m
and 2 700 m above sea level.
Switch settings
When using at an altitude of less
[OFF]
than 1 400 m above sea level
When using at high altitudes
[ON]
(between 1 400 m and 2 700 m
above sea level)
Note
The fan rotation and operating noise increases if set to
z
[ON].
Switch settings