Mitsubishi Electric PH50 series Setup And Installation Manual page 42

Dlp data display cube
Table of Contents

Advertisement

1.5.1.11. INDICATION
This adjustment is normally unnecessary.
Used to set how to indicate the status information.
1.5.1.11.1. WARNING (for
This is to set the indication of a warning mark on screen to induce to replace the spare lamp after
auto-lamp changing or pre-announcement of the changing ("2.1.3.5 Warning indication", on page
82).
OFF: No indication.
MESSAGE, ☀: To display both pre-announcement of auto-lamp changing and a warning
mark to induce to replace the spare lamp.
☀: To display only the warning mark.
[Procedure]
1.
Select WARNING in INDICATION in MISC FUNCTION in the system menu.
2.
Set OFF, MESSAGE ☀ or ☀.
1.5.1.11.2. STANDBY
This is to set a blue LED indication on screen ("3.5 LED display", on page 93) at stand-by state.
LED: To light the blue LED on screen.
OFF: No indication.
[Procedure]
1.
Select STANDBY in INDICATION in MISC FUNCTION in the system menu.
2.
Set LED or OFF.
1.5.1.11.3. ERROR
This is to set a blue LED indication on screen ("3.5 LED display", on page 93) at shutdown due to
errors.
LED: To blink the blue LED on screen.
OFF: No indication.
[Procedure]
1.
Select ERROR in INDICATION in MISC FUNCTION in the system menu.
2.
Set LED or OFF.
1.5.1.11.4. BLOWOUT (for
This is to set a blue LED indication on screen ("3.5 LED display", on page 93) at lamp blowout
when BLOWOUT (chapter 1.5.1.13, on page 43) is set OPERATE.
LED: To blink the blue LED on screen.
OFF: No indication.
[Procedure]
1.
Select BLOWOUT in INDICATION in MISC FUNCTION in the system menu.
2.
Set LED or OFF.
PH50, XL50, XL21 series Set-up and Installation Manual
C
h
a
n
g
e
r
)
C
h
a
n
g
e
r
X
X
L
L
2
2
1
1
or when the input board is selected in
42
P
P
H
H
5
5
0
0
and
X
X
L
L
5
5
0
0
)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xl50 seriesXl21 series

Table of Contents