1.2.5. Cube stacking (for
1.2.5.1. Preassembly (for
1.2.5.1.1. Shorten the depth of cube cabinet
This work is normally unnecessary.
You can shorten the depth of the
gate or door. The depth of the cube cabinet can be reduced from 865mm to 684mm.
1.
Loosen 4 screws to unlock the lock brackets
for screen fixing bolts.
2.
Pull out the 4 screen fixing bolts from rear. Be sure not to
drop the 4 washers which are attached to the tip of the bolts.
3.
Unscrew 4 hexagon socket head bolts (5mm) to detach the
front attachment.
PH50, XL50, XL21 series Set-up and Installation Manual
R
e
a
r
)
R
e
a
r
8
8
0
0
"
"
)
8
0
"
cube cabinet when you pass the cubes through a narrow
8
0
"
10
Screw
Lock bracket
Screen fixing bolt
Washer
Front attachment
Hexagon socket
head bolt