Auto-Lamp Changing Function (For C H A N G E R ) - Mitsubishi Electric PH50 series Setup And Installation Manual

Dlp data display cube
Table of Contents

Advertisement

2.1.3. Auto-lamp changing function (for
C
C
h
h
a
a
n
n
g
g
e
e
r
r
is equipped with the auto-lamp changing function that can detect a lamp failure or a
brightness deterioration to swap it for a spare lamp automatically.
The lamp is managed as three types of status, "NEW", "USED" and "JUNK". It is displayed on
screen by [DISPLAY] button.
NEW:
New or not-deteriorated lamp
USED:
Deteriorated lamp below the threshold set in CHANGE MODE menu (chapter
1.5.1.18.2, on page 45)
JUNK:
Failed lamp
5 minutes after the auto-lamp changing, the lamp can be automatically adjusted to the suitable
position to maximize the brightness (chapter 2.1.3.4, on page 81), and the initial brightness is
automatically read. If you turn off the power during the auto-lamp changing, the initial value will
be read in the same way when you will turn on again.
2.1.3.1. Action in lamp failure (burnout or explosion)
When a lamp failure is detected, the lamp is automatically swapped for a spare lamp.
1.
When it detects a lamp failure, the lamp status is automatically recognized as "JUNK" and
memorized in the lamp memory.
2.
If the spare lamp status is "NEW" or "USED", the auto-lamp changing starts. "☀" mark starts
blinking on the screen to induce to replace the spare lamp (chapter 2.1.3.5, on page 82).
3.
If the spare lamp status is "JUNK", the product tries to ignite the current lamp once without
auto-lamp changing. If it succeeds to ignite, it continues to work. Otherwise, the error
indicator shows "1." (chapter 3.5, on page 93).
Even if the status is "JUNK", in the case that you have cycled the power during this status,
the auto-lamp changing starts. If it succeeds to ignite, it continues to work. Otherwise, the
error indicator shows "1.".
2.1.3.2. Action in brightness deterioration
When the luminous sensor detects a brightness deterioration, the lamp is automatically swapped
for a spare lamp.
1.
When the luminous sensor detects brightness deterioration, the lamp status is automatically
recognized as "USED" and memorized in the lamp memory.
2.
If the spare lamp status is "NEW", the pre-announcement of auto-lamp changing is displayed
on screen and the auto-lamp changing starts 5 minutes later. "☀" mark starts blinking on the
screen to induce to replace the spare lamp (chapter 2.1.3.5, on page 82).
3.
If the spare lamp status is "USED" or "JUNK", the current lamp is not swapped to keep
lighting.
In CHANGE MODE menu (chapter 1.5.1.18.2, on page 45), you can set the brightness to start
the auto-lamp changing. There are three types of condition, 50% of initial brightness (NORMAL),
30% of initial brightness (LONG) or no swap due to brightness deterioration (OFF). The initial
setting is NORMAL.
PH50, XL50, XL21 series Set-up and Installation Manual
C
h
a
n
g
e
r
)
C
h
a
n
g
e
r
80

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xl50 seriesXl21 series

Table of Contents