1.4.3.2. 6-axis adjustment
1.4.3.2.1. Release the lock screws
Before 6-axis adjustment, release locks
in the adjuster. Loosen 4 locking screws
with an Allen wrench (2mm) and 5 fixing
screws with an Allen wrench (4mm).
1.4.3.2.2. When adjusting with motorized adjustment tool, S-AXL50E
Attaching
1.
Set the rotary dial in the upper unit
of the adjustment tool according to
the product (chapter 3.8.4.2, on
page 99). The initial setting is 0.
F
r
o
n
t
: Set it 0.
F
r
o
n
t
R
e
a
r
: Set it 1.
R
e
a
r
2.
Make sure the slide switch is set
OPE (right side).
3.
Connect the upper and lower units with a supplied
unit-connecting cable.
Connect a supplied cube-connecting cable with upper
4.
unit.
5.
Open the screen (chapter 1.2.7.1, on page 23) or rear
panel to access the 6-axis adjuster.
Note:
For
R
e
a
r
, open the rear panel 180 degrees or
R
e
a
r
remove it to perform the adjustment. Adjustment with
half-open panel may cause breakage due to
interference with the adjustment tool.
4 locking screws
Rear panel
31
Slide switch
POWER
OPE
RESET
F ACTORY
ERROR
Upper unit
Lower unit
Cube-connecting cable
5 fixing screws
Rotary Dial
0 : FRONT
1 : REAR
FW-EN
9 : TEST
Unit-connecting cable
REV 2.5