Concatenation Of Multiple Commands; Responses; Examples Of Query Commands - Hand Held Products IMAGETEAM 5620 System Manual

Hand held products, inc. system manual cordless system 2020, 5620
Hide thumbs Also See for IMAGETEAM 5620:
Table of Contents

Advertisement

Concatenation of Multiple Commands

Multiple commands can be issued within one Prefix/Storage sequence. Only the
Tag, SubTag, and Data fields must be repeated for each command in the
sequence. If additional commands are to be applied to the same Tag, then the
new command sequence is separated with a comma (,) and only the SubTag and
Data fields of the additional command are issued. If the additional command
requires a different Tag field, the command is separated from previous
commands by a semicolon (;).

Responses

The device responds to serial commands with one of three responses:
ACK Indicates a good command which has been processed.
ENQ Indicates an invalid Tag or SubTag command.
NAK Indicates the command was good, but the Data field entry was out of the
allowable range for this Tag and SubTag combination, e.g., an entry for a
minimum message length of 100 when the field will only accept 2
characters.
When responding, the device echoes back the command sequence with the
status character inserted directly before each of the punctuation marks (the
period, exclamation point, comma, or semicolon) in the command.

Examples of Query Commands

In the following examples, a bracketed notation [ ] depicts a non-displayable
response.
Example #1:What is the range of possible values for Codabar Coding Enable?
Enter:
cbrena*.
Response:
CBRENA0-1[ACK]
This response indicates that Codabar Coding Enable (CBRENA) has a range of
values from 0 to 1 (off and on).
Example #2: What is the default value for Codabar Coding Enable?
Enter:
cbrena^.
Response:
CBRENA1[ACK]
This response indicates that the default setting for Codabar Coding Enable
(CBRENA) is 1, or on.
Example #3: What is the device's current setting for Codabar Coding Enable?
Enter:
cbrena?.
Response:
CBRENA1[ACK]
This response indicates that the device's Codabar Coding Enable (CBRENA) is
set to 1, or on.
IMAGETEAM™ 2020/5620 System Manual
10 - 3