7)
Location of Insulations
a)
Place 1 piece of Insulation behind the Mantel Top.
b)
Cut the second piece of Insulation in half, then install behind both
the Left and Right Sides as shown.
8)
The unit may now carefully be slid into fi nal position.
Hampton HI300 Wood Cast Insert
Insulation
RECOMMENDED MEASUREMENTS FOR
SETTING SIDE CASTS
Stop! Read Carefully.
Enamel & Cast components are very fragile. Use
extreme care when handling.
1/4" (approx.) between both sides of door
and cast.
Left Side
Cast
1/8" - 1/4" (approx.) for both sides, between
ashlip and bottom of side cast.
Rear View of Unit
4-1/2" - 4-3/4" boths sides rear inside edge to fi rebox.
Important: Verify gap between cast and door did not
change when rear adjustments have been made.
Carefully open door slowly, to ensure that the door does
not rub against cast sides.
*
These are just recommended measurements.
INSTALLATION