3.
Connect ground wire (green or bare) of direct wire cable
to external ground conductor screw. Tighten screw.
E
F
4.
A. External ground conductor
screw
B. Ground wire (green or bare) of power supply cord
C. Neutral ground wire
D. Center silver-colored
terminal block screw
E. Neutral wire (white or center)
F. 3/4"(19 mm) UL listed strain refief
Place the hooked ends of the other power supply cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
5. Tighten strain relief screw.
6. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
7. You have completed your electrical connection. Now go to
"Venting Requirements."
r
3-wire connection:
Power supply cord
Use where IocaJ codes permit connecting
cabinet-ground
conductor
to neutral wire.
C
D
E
G
F
A. 3-wire receptacle
(NEMA type 10-30R)
B. 3-wire plug
C. Neutral prong
D. Spade terminals with upturned
ends
E. 3/4" (19 mm) UL listed strain relief
F. Ring terminals
G. Neutral (white or center wire)
1.
2.
Loosen or remove center silver-colored
terminal block screw.
Connect neutral wire (white or center wire) of power supply
cord to the center silver-colored terminal screw of the terminal
block. Tighten screw.
A
A. External ground conductor
screw
B. Neutral ground wire
C. Center silver-colored
terminal block screw
D. Neutral wire (white or center wire)
E. 3/4" (19 mm) UL fisted strain relief
3. Connect the other wires to outer terminal block screws.
Tighten screws.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. You have completed your electrical connection. Now go to
"Venting Requirements."
3-wire connection:
Direct Wire
Use where local codes permit connecting
cabinet-ground
conductor
to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so
washer/dryer can be moved if needed.
Strip 31/2'' (89 mm) of outer covering from end of cable. Strip
insulation back 1" (25 mm) if using 3-wire cable with ground wire,
cut bare wire even with outer covering. Shape ends of wires into a
hook shape.
kktkkttttkL >:
,_ ..........3A .....
{s9 _m_
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together, and tighten screw, as shown.