2.
3.
Loosen or remove center silver-colored
terminal block screw.
Place the hooked end of the neutral wire (white or center wire)
of direct wire cable under the center screw of terminal block
(hook facing right). Squeeze hooked end together. Tighten
screw.
C
B...............
A. External ground conductor screw
B. Neutral ground wire
C. Center silver-colored
terminal block screw
D. Neutral wire (white or center wire)
E. 3/4" (19 mm) UL listed strain refief
Place the hooked ends of the other power supply cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
!!
4. Tighten strain relief screw.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6.
You have completed your electrical connection. Now go to
"Venting Requirements."
Use for direct wire or power supply cord where Ioca_ codes
do not permit connecting cabinet-ground
conductor to
neutral wire.
1. Remove centersilver-colored
terminal block screw.
2.
Remove neutral ground wire from external ground conductor
screw. Connect neutral ground wire and the neutral wire (white
or center wire) of power supply cord/cable under center,
silver-colored
terminal block screw. Tighten screw.
E
3.
A. External ground conductor
screw
B. Neutral ground wire
C. Neutral wire (white or center wire)
D. Grounding path determined by a quafified electrician
E. 3/4" (19 mm) UL listed strain relief
Connect the other wires to outer terminal block screws.
Tighten screws.
!!
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6.
Connect a separate copper ground wire from the external
ground conductor screw to an adequate ground.
10