Download Print this page

Maytag MET3800TW2 Installation Instructions Manual page 14

27"(69cm)electric washer/dryer
Hide thumbs Also See for MET3800TW2:

Advertisement

Available languages

Available languages

1. Move the washer/dryer
to its final location and remove any
cardboard used to move the washer/dryer.
2. Locate the remaining piece of shipping strap. See "Remove
Shipping Strap."
3=
Shipping strap
Wrap the drain hose to the laundry tub leg or standpipe with
the shipping strap (A or B below). Push fastener into the
nearest hole in the shipping strap (see illustration above).
A
B
C
If the water faucets and the drain standpipe are recessed, put
the hooked end of the drain hose in the standpipe. Tightly
wrap the shipping strap around the water inlet hoses and the
drain hose (C above). Push fastener into the nearest hole in
the shipping strap (see illustration above).
Choose your exhaust installation type
Recommended
exhaust
installations
Typical installations vent the dryer from the rear of the washer/
dryer. Other installations are possible.
.......................
O
A
................................................
C ...............
_
H
A. Dryer
B. Rigid metal or flexible metal vent
C. Clamps
D. Wall
E. Elbow
F. Clamps
G. Elbow
H. Exhaust hood
Optional
exhaust
installations
This washer/dryer
can be converted to exhaust out the right
or left side. To convert the washer/dryer, use Side Exhaust Kit
Part Number 279823. If your washer/dryer
was previously
exhausted from the right or left side, it can be converted to rear
exhaust by using standard offset connections. To cover the hole
in the side, one of the following plugs can be added:
692790 (white)
3977784 (biscuit)
Follow the instructions in the kit to install. Kits are available from
the dealer from whom you purchased your washer/dryer.
A
B
C
A. Standard rear offset exhaust installation
B. Rear exhaust for offset close clearance connection
C. Left or right side exhaust instaflation
Alternate
installations for close clearances
Venting systems come in many varieties. Select the type best for
your installation. Three close-clearance
installations are shown.
Refer to the manufacturer's
instructions provided with the vent
system.
= ii:i i
"
,,
A
B
C
A. Loop system with standard elbows
B. Loop system with one offset and one standard elbow
C. Vent system with one periscope
(2" [51 mm] clearance)
NOTE: The following kits for close clearance alternate installations
are available for purchase. Please reference the "Assistance or
Service" section of the Washer/Dryer User Instructions.
[]
Over-the-Top Installation:
Part Number 4396028
Periscope Installation (For use with dryer vent to wall vent
mismatch):
Part Number 4396037 - 0" (0 mm) to 18" (457 mm) mismatch
Part Number 4396011 - 18" (457 mm) to 29" (737 mm)
mismatch
Part Number 4396014 - 29" (737 mm) to 50" (1.27 m)
mismatch
14

Advertisement