Step 7: Burner Test and Adjustment
Install any loose components,
such as burner caps
and grates
that may have been removed
earlier.
Be certain
that burner
caps seat properly
into the
burner bases. Before testing operation
of the appli-
ance, verify that the unit and the gas supply
have
been carefully
checked
for leaks and that the unit
has been connected
to the electrical
power
sup-
ply. Turn the manual
gas shut-off valve to the open
position.
Test
Cooktop
Burners
Test
Burner
Ignition.
Select
a cooktop
burner
knob.
Push
in and turn
counterclockwise
to HI.
The
ignitor/spark
module
will produce
a clicking
sound.
Once
the air has been purged
from
the
supply lines, the burner should
light within four (4)
seconds.
Test Flame:
High
Setting.
Turn burner on to HI.
See Figure
13 for appropriate
flame
characteris-
tics.
If any of the cooktop
burners
continue
to burn
mostly or completely
yellow,
verify that the burner
cap is positioned
properly
on the burner base, then
re-test.
If flame characteristics
do not improve,
call
Thermador@.
Test Flame:
Low
Setting.
Turn burner
on to LO.
Verify
that the
flame
completely
surrounds
the
burner.
There
should
be a flame at each
burner
port and there
should
be no air gap between
the
flame and the burner.
If any burners
do not carry
over, call Thermador®.
The two far left burners
feature XLO®, causing the
flame to cycle on and off when the knob is set to
the XLO range. This is normal operation.
Repeat
the Ignition
and Flame
Test procedures
described
above for each cooktop
burner and the
grill burner (if so equipped).
FiG. 13
Flame Characteristics
Yellow Flames:
Further adjustment is required.
Yellow Tips on Outer Cones:
Normal for LP Gas.
Soft Blue Flames:
Normal for Natural Gas.
If the flame
is completely
or mostly
yellow,
verify that the regulator
is set for the correct
fuel. After adjustment,
retest.
Some
orange-colored
streaking
is normal
during the initial start-up.
Allow unit to operate
4-5 minutes and re-eval-
uate before making
adjustments.
WHEN
FLAME
IS PROPERLY
ADJUSTED:
.
There
should
be a flame
at each burner
port.
.
There
should
be no air gap between
the
flame
and burner
port.
The gas grill uses a tube-style
burner that has an
air shutter which allows adjustment
to the amount
of primary
air inside the burner tube.
Air shutters
of tube-style
burners
are pre-adjust-
ed at the factory,
and usually
do not require
re-
adjustment
except under rare conditions
such as
installation
at high altitude.
If grill burnedftame
adjustment
is required,
go
to the
procedure:
"Flame Adjustment
(if neces-
sary)".