Step 4: Gas Requirements
and Hookup
Cooktops
are shipped
by the factory
to operate
on natura_ gas. They must
be converted
for use
with propane.
Verify the type of gas being
used
at the installation
site matches
the type of gas
used
by the appliance,
If the Eocat{onijob site re-
quires conversion
from natural gas to propane (LP),
contact
the dealer where
the unit was purchased
or contact Thermador.
The field conversion
kit for
all Professional
cooktops
(PC series) is Thermador
Model PLPKIT. Obey all instructions
in PLPKIT for
correct conversion
of the gas regulator
and settings
for the gas valves.
Field conversion
must be done
by qualified
service
personnel
only.
This appliance
has been CSA certified for safe op-
eration up to an elevation
of 10,200 ft. without
any
modifications.
Exception:
For usewith
propane, the
appliance
must be converted
per the LP conversion
instructions.
Please refer to your LP Conversion
Instructions
for
further
information.
Natural
Gas Requirements:
Inlet Connection:
1/2" NPT (min. 3/4" dia. flex line)
Supply Pressure:
6" min. to 14" max. water
column (14.9 to 34.9 mb)
Manifold Pressure:
5" water column (12.5 mb)
Propane
Gas Requirements:
Inlet Connection:
I/2" NPT (min. 3/4" dia. flex line)
Supply Pressure:
11" min. to 14" max. water
column (27.4 mb to 34.9 mb)
Manifold Pressure:
10" water column (24.9 mb)
WARNING"
This conversion
kit shall be installed
by
a qualified
service agency in accordance
with the manufacturer's
instructions
and
all applicable
codes
and requirements
of the authority
having jurisdiction.
If the
information
in these
instructions
is not
followed
exactly, a fire, explosion
or pro-
duction
of carbon
monoxide
may result
causing
property
damage,
personal
in-
jury or loss of life. The qualified
service
agency
is responsible
for the proper
in-
stallation
of this kit. The installation
is not
proper and complete
until the operation
of the converted
appliance
is checked
as
specified
in the manufacturer's
instruc-
tions supplied
with the kit.
HOOK
UP
A manual
gas shut-off
valve must be installed
external
to the appliance,
in a location
acces-
sible from the front, for the purpose
of shutting
off the gas supply.
The supply
line must not
interfere with the back of the unit. Make sure the
gas supply is turned
off at the manual
shut-off
valve before connecting
the appliance.
The installer should inform the consumer
of the
location of the gas shut-off valve. Make sure all
users know where and how to shut off the gas
supply to the cooktop.
The gas supply connections
shall be made by
a competent
technician
and in accordance
with
local codes or ordinances.
In the absence
of a
local code, the installation
must conform
to the
National Fuel Gas CodeANSI
Z223.1iNFPA54=
current
issue.
Always
use pipe-sealing
compound
or Teflon _
tape on the pipe threads,
and be careful not to
apply excessive
pressure
when tightening
the
fittings.
Leak
testing
of the
appliance
shall
be in
accordance
with the following
instructions.
Turn on gas and check supply line connections
for leaks using a soap and water solution.
Bubbles
forming
indicate
a gas leak. Repair
all leaks immediately
after finding
them.
Do not use a flame
of any kind
to check
for gas _eaks.
All installer-supplied
parts
must
conform
to
applicable
codes.