Performance Two---Stage, Variable Speed
4---Way Multipoise
Condensing Gas Furnace
Series 1
The 59TP6A Multipoise Variable- -Speed Condensing Gas Furnace
features the two- -stage Performancet System. The Comfort HeatR
technology two- -stage gas valve is at the heart of the comfort
provided by this furnace, along with the variable- -speed ECM
blower motor, and two- -speed inducer motor. With an Annual Fuel
Utilization Efficiency (AFUE) up to 96.5%, the Performancet
Series two- -stage gas furnace provides exceptional savings when
compared to standard gas furnaces. This Performance Gas Furnace
also features 4- -way multipoise installation flexibility, and is
available in eight model sizes. The 59TP6A can be vented for
direct vent/two- -pipe, ventilated combustion air, or single- -pipe
applications. All units meet California Air Quality Management
District emission requirements. All sizes are design certified in
Canada.
STANDARD FEATURES
S All sizes meet ENERGY STARR Version 4.0 criteria for gas
furnaces: 95+AFUE; AMACF electrical rating; 2% or less
Product Data
TM
cabinet airflow leakage.
S Quiet operation. Compare for yourself at HVACpartners.com.
S Ideal height 35" (889 mm) cabinet: short enough for taller coils,
but still allows enough room for service.
S Silicon Nitride Perfect Light Hot Surface Igniter.
S SmartEvap technology helps control humidity levels in the
home when used with a compatible humidity control system.
S ComfortFan technology allows control of continuous fan
speed from a compatible thermostat.
S 4- -way multipoise design for upflow, downflow or horizontal
installations, with unique vent elbow and optional through- -
the- -cabinet downflow venting capability.
S Full- -featured variable- -speed blower motor, two- -speed inducer
motor, and two- -stage gas valve.
S Self- -diagnostics.
S Adjustable blower speed for cooling, continuous fan, and
dehumidification.
S Aluminized- -steel primary heat exchanger.
A11263
S Stainless- -steel condensing secondary heat exchanger.
S Propane convertible (See Accessory list).
S Factory- -configured ready for upflow applications.
S Fully- -insulated casing including blower section.
S Convenient Air Purifier and Humidifier connections.
S Direct- -vent/sealed combustion, single- -pipe venting or
ventilated combustion air.
S Installation flexibility: sidewall or vertical vent.
S Residential installations may be eligible for consumer financing
through the Retail Credit Program.
S Certified to leak 2% or less of nominal air conditioning CFM
delivered when pressurized to 1- -in. water column with all
present air inlets, air outlets, and condensate drain port(s) sealed.
1

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 59TP6A

  • Page 1 4- -way multipoise installation flexibility, and is S Installation flexibility: sidewall or vertical vent. available in eight model sizes. The 59TP6A can be vented for direct vent/two- -pipe, ventilated combustion air, or single- -pipe S Residential installations may be eligible for consumer financing applications.
  • Page 2: Technical Data

    Control is a proprietary function that promotes homeowner shell primary heat exchanger was re- -engineered to achieve greater comfort through two stages of heating. This Carrier furnace offers a efficiency out of a smaller size. The first two passes of the heat...
  • Page 3: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE Example of Model Number 1 - 2 7 - 9 11 - 12 15 - 16 Family Htg. Stages Tier Major Series Htg. Cap. Motor Width Base Effy. Voltage Minor Series Airflow 08 - 800 CFM Family 10 - 1000 CFM 12 - 1200 CFM S - Single Stage...
  • Page 4: Specifications

    SPECIFICATIONS Heating Capacity and Efficiency 040-10 040-12 060-12 060-14 080-16 080-20 100-20 120-22 High Heat (BTUH) 40,000 40,000 60,000 60,000 80,000 80,000 100,000 120,000 Input Low Heat (BTUH) 26,000 26,000 39,000 39,000 52,000 52,000 65,000 78,000 High Heat (BTUH) 39,000 39,000 58,000 58,000...
  • Page 5 FILXXCAR0020 Use with FILCABXL ---1020 Cartridge Media Filter - 24” (610 mm) FILXXCAR0024 Use with FILCABXL ---1024 Carrier Infinity Air Purifier - 16x25 (406x635 mm) GAPAAXCC1625-A08 Up to 1600 CFM Carrier Infinity Air Purifier - 20x25 (508x635 mm) GAPAAXCC2025-A08 Up to 2000 CFM Carrier Infinity Air Purifier Repl.
  • Page 6 AIR DELIVERY - - CFM (SW1-5 and SW2---2 set to OFF, except as indicated. See notes 1 and 2) Cooling Switch Settings External Static Pressure (ESP) Unit Size SW2-8 SW2-7 SW2-6 1.030 040---10 Clg Default: 1125 1080 1020 note 8 Cooling (SW2) 1125 1080...
  • Page 7: Clg Sw2: Maximum Clg Airflow

    AIR DELIVERY - - CFM (CONTINUED) Cooling Switch Settings External Static Pressure (ESP) Unit Size SW2-8 SW2-7 SW2-6 060---14 Clg Default: 1330 1295 1260 1220 1190 1150 1110 1075 1045 1005 See note 4 See note 4 Cooling (SW2) 1160 1120 1090 1045...
  • Page 8: High Heat Airflow

    AIR DELIVERY - - CFM (CONTINUED) Cooling Switch Settings External Static Pressure (ESP) Unit Size SW2-8 SW2-7 SW2-6 100- - 20 Clg Default: 1890 1845 1800 1755 1700 1655 1610 1560 1510 1460 1015 See note 4 1080 See note 4 1155 1080 1020...
  • Page 9: See Note

    MAXIMUM EQUIVALENT VENT LENGTH - - FT. (M) NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows. Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application. Table 1 –...
  • Page 10: Venting System Length Calculations

    Venting System Length Calculations The Total Equivalent Vent Length (TEVL) for EACH combustion air or vent pipe equals the length of the venting system, plus the equivalent length of elbows used in the venting system from Table 2. Standard vent terminations or factory accessory concentric vent terminations count for zero deduction. See vent system manufacturer’s data for equivalent lengths of flexible vent pipe or other termination systems.
  • Page 11 MAXIMUM EQUIVALENT VENT LENGTH - - FT. (M) (CONTINUED) NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows. Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application. Table 3 –...
  • Page 12: Note

    MAXIMUM ALLOWABLE EXPOSED VENT LENGTHS INSULATION TABLE - - FT. (M) No Insulation 3/8-in. (9.5 mm) 1/2-in. (12.7 mm) Two Stage Pipe Pipe Diameter-inches (mm) Pipe Diameter-inches (mm) Pipe Diameter-inches (mm) Winter Design Furnace High Length in Temp ° F (° C) Heat Input Ft.
  • Page 13: Note

    RETURN AIR TEMPERATURE This furnace is designed for continuous return- -air minimum temperature of 60_F (15_C) db or intermittent operation down to 55_F (13_C) db such as when used with a night setback thermometer. Return- -air temperature must not exceed 80_F (27_C) db. Failure to follow these return air limits may affect reliability of heat exchangers, motors and controls.
  • Page 14 Carrier cased coil is used. It is combustion air to be drawn in through the outer pipe.
  • Page 15 OPTIONAL MEDIA FILTER CABINET 25-5/8" (651mm) 24-1/4” 23-5/8" (616mm) (600mm) Opening with Flanges Bent 23-1/8” 23-3/8” (588mm) (594mm) Opening Duct Side Furnace Side 23-3/4” (603mm) " Centerline Screw Slots Media Filter (146mm) Cabinet 17" (432mm) 16" (406mm) 16" (406mm) 20" (508mm) 21"...
  • Page 16: Dimensional Drawing

    DIMENSIONAL DRAWING A12267 59TP6A SHIP WT. FURNACE SIZE LB (KG) CABINET WIDTH OUTLET WIDTH BOTTOM INLET WIDTH AIR INTAKE 040--- 10 121.0 (55.0) 14--- 3/16 (361) 12--- 1/2 (319) 12--- 9/16 (322) 7--- 1/8 (181) 040--- 12 130.5 (59.2) 060--- 12 131.5 (59.6)
  • Page 17 GUIDE SPECIFICATIONS General System Description Primary Heat Exchangers Furnish a ______________________ 4- -way multipoise gas- -fired Primary heat exchangers shall be 3- -Pass corrosion- -resistant condensing furnace for use with natural gas or propane (factory- - aluminized steel of fold- -and- -crimp sectional design and applied authorized conversion kit required for propane);...
  • Page 18 Catalog No: 59TP6A ---02PD Copyright 2014 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Edition Date:08/14 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Replaces: 59TP6A--- 01PD...

Table of Contents