IGNITER ASSEMBLY

1.
Remove burner access panel. See Fig. 18.
FIG. 18
2. The igniter assembly is located at the top of the
burner casting. Remove the screws securing the
mounting bracket to the burner. See Fig. 19.
FIG. 19
5/32 IN. IGNITER BOTTOM
5/32 IN IGNITOR BOTTOM
SCREWS
TO BURNER TOP
TO BURNER TOP
IGNITOR/SENSOR
IGNITOR CABLE
ELECTRODE GAP IS 1/8 IN.
ELECTRODE GAP IS 1/8 IN
AND CENTERED OVER BURNER PORT
AND CENTERED OVER BURNER PORT
17
FIG. 20
MOUNTING
BRACKET
BURNER
PORT
3.
Disconnect high voltage ignition lead. Remove the
mounting screws. See Fig. 20.
SCREWS
IGNITION LEAD END
The igniter and ground rod should be cleaned during
routine maintenance to maintain proper ignition.
-- Use steel wool or emery cloth.
-- Rub briskly to remove buildup of dust, dirt , and oxide.
Check the igniter's ceramic base for cracks.
-- Replace the igniter if cracks are found.