Installation Options:
¥ Insert into a Masonry Fireplace
Features:
¥ EPA Phase II Approved
¥ 3.1 Cubic Foot Firebox Volume
¥ Single, Push/Pull Operating Control
¥ Accepts Logs Up to 24" Long
Heating Specifications:
Approximate Maximum Heating Capacity (in square feet)*
Maximum BTU's per Hour (Cord Wood Calculation)
Overall Efficiency (Oregon Method)
Maximum Burn Time (Hours)
*
Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside temperature. It is also
affected by the quality and moisture level of the fuel.
Dimensions:
Flue is centered on the stove and 5 5/8"
from the rear edge of the appliance.
(Use 6" Dia. Pipe)
Height*:
21 3/4"
*Older model panels may use the heightened yoke, adding 7/8" to the height. Furthermore,
allow an additional height to align the pipe on positive and direct connect installations.
Emissions:
2.6 Grams Per Hour (EPA Phase II Approved) Ð Tests conducted by E.E.S.P.C. Lab.
F
EATURES AND
¥ Long Burn Time - Up to 12 Hours
¥ 5/16 to 3/16" Steel Construction
¥ Heavy Duty Refractory Firebrick
¥ Optional High-Tech Blower
29 1/4"
43 3/4"
S
PECIFICATIONS
1,200 to 2,250
74,300
70%
12
Weight:
470 Pounds
15 3/4"
Rear edge of
surround panel
4 3/4"
Faceplate
Measure all side
clearances from
here.
P
5
AGE