Touch-Up Paint; Blower Cleaning; Firebrick And Baffle Inspection And Cleaning - Travis Industries Freedom Bay Owner's Manual

Masonry fireplace insert
Table of Contents

Advertisement

M
AINTAINING
P
22
AGE
T
-U
P
OUCH
P
AINT
Included with the owner's pack of this appliance is a can of
Stove-BriteÒ paint. To touch up nicks or dulled paint, apply
the paint while the appliance is cool. Use 120 grit sandpaper
(clean with water and dry with a piece of cloth) if the surface
requires smoothing. Wait at least one hour before starting the
appliance. The touched up area will appear darker than the
surrounding paint until it cures from heat. Curing will give off
some fumes while curing Ð open windows to ventilate the
fumes.
B
C
LOWER
LEANING
The blower for this appliance will gather dust as it circulates air. Before cleaning, remove the blower
from the appliance (see "Blower Installation" on page 8). Remove all dust and debris from the blower
grill and around the interior of the blower.
F
A
B
IREBRICK
ND
With the appliance cool, remove all ash from the firebox and scrape away any scale that may have built
up on the surface of the firebrick with a wire brush or scraper. Any of the firebrick on the floor or walls
of the firebrick that is cracked must be replaced (see the section "Firebrick Removal and Replacement
Instructions"). Next, inspect the baffle components. The illustration below details the areas that must be
inspected. If any of the components need to be replaced, see the section "Baffle Removal and
Replacement Instructions".
BYPASS ASSEMBLY
Entire assembly must be
properly aligned and correctly
oriented.
BAFFLE FIREBRICKS
Must not be cracked or have
gaps between them. Cracked
bricks must be replaced. Gaps
are eliminated by pushing the
bricks closer together.
SECONDARY AIR TUBES
Must be intact without any
cracks. Scaling and a slight
amount of bending is normal
for this component.
BAFFLE SUPPORTS
Must be snug against the baffle
firebricks and resting on the
secondary air collars.
SECONDARY AIR TUBE COLLARS
Must have the two push pins inserted into them.
This keeps the secondary air tubes aligned.
Y
A
OUR
PPLIANCE
I
AFFLE
NSPECTION
(C
ONTINUED
A
C
ND
LEANING
FLOOR & WALL FIREBRICKS
Must not be cracked or severely
chipped (damaged bricks must be
replaced). Remove any scaling or
buildup with a scraper or wire brush.
)
Touch-Up
P a i n t

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lopi freedom bay

Table of Contents