Travis Industries Flush Wood Plus Owner's Manual

Flush wood plus insert (rectangular)
Hide thumbs Also See for Flush Wood Plus:
Table of Contents

Advertisement

Quick Links

Flush Wood Plus Insert

SAFETY NOTICE:

If this appliance is not properly installed, a house fire may
result. For your safety, follow the installation directions.
Contact local building or fire officials about restrictions and
installation inspection requirements in your area.
Travis Industries, Inc.
12521 Harbour Reach Drive
Mukilteo, WA 98275
www.travisproducts.com
(Rectangular)
Owner's Manual
 Masonry Fireplace Insert
 Zero-Clearance (Metal) Fireplace Insert
Save these instructions for future reference
 Copyright 2015, T.I.
$10.00
100-01259
4150520
Listed
Tested to: U.L. 1482 & ULC S628

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Flush Wood Plus and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Travis Industries Flush Wood Plus

  • Page 1: Safety Notice

    Flush Wood Plus Insert (Rectangular) Owner's Manual  Masonry Fireplace Insert  Zero-Clearance (Metal) Fireplace Insert Save these instructions for future reference SAFETY NOTICE: If this appliance is not properly installed, a house fire may result. For your safety, follow the installation directions.
  • Page 2: General Information Introduction & Important Information

    Or, mail your warranty card to: This serial number will be needed in case you require Travis Industries House of Fire service of any type. 12521 Harbour Reach Drive Mukilteo, WA 98275 Model: Flush Wood Plus Save Your Bill of Sale.
  • Page 3: Table Of Contents

    Blower and Electrical Parts ........28 Firebox Parts .............. 28 Baffle Removal and Replacement ......29 Air Tube Removal and Replacement ......30 Brick Removal & Replacement ........31 Warranty ............... 32 Listing Information ............ 34 Index ................36 © Travis Industries 100-01259 4150520...
  • Page 4: Safety Precautions

    (UL 103 HT) Clay cause a house fire. residential type chimney or an Liner Do not connect this appliance to approved masonry chimney with any chimney serving another a standard clay tile, or stainless appliance. steel liner. © Travis Industries 100-01259 4150520...
  • Page 5: Travis Industries

    Always follow the instructions in this manual. Travis Industries, Inc. grants no warranty, implied or stated, for the installation or maintenance of your appliance, and assumes no responsibility of any consequential damage(s).
  • Page 6: Features & Specifications

    This heater meets the 2015 U.S. EPA’s crib wood emission limits for wood heaters sold after May 15, 2015. Tested to Method 28, 5G1 this heater has been shown to deliver heat at rates ranging from 12,100 to 29,600 BTU/hr and an emission value of 4.4g/h. © Travis Industries 100-01259 4150520...
  • Page 7: Fireplace Insert Installation

    Planning The Installation We suggest that you have an authorized Travis Industries dealer install your fireplace insert. If you install the fireplace insert yourself, your authorized dealer should review your installation plans. Check with local building officials for any permits required for installation of this fireplace insert and notify your insurance company before proceeding with installation.
  • Page 8: Fireplace Requirements

    Attach the "This fireplace has been altered..." plate to the fireplace (use two screws or other suitable method). You may wish to place it in a location where it will be covered by the surround panels. © Travis Industries 100-01259...
  • Page 9: Insert Placement Requirements

    Chimney height: 15' (4.5M) minimum; 33' (10M) maximum (measured from base of insert).  Entire fireplace, including chimney, must meet local building requirements.  The fireplace insert must be placed on a masonry hearth built to UBC standards. © Travis Industries 100-01259 4150520...
  • Page 10: Zero-Clearance (Metal) Fireplace Requirements

    Inadequate draft may cause backpuffing into the room and `plugging' of the chimney. Inadequate draft will cause the appliance to leak smoke into the room through appliance and chimney connector joints. An uncontrollable burn or excessive temperature indicates excessive draft. © Travis Industries 100-01259 4150520...
  • Page 11: Insert Rollers

    Flue Bracket components to secure the flue to the They are secured from fireplace insert. inside the firebox, making Self-Drilling Screws installation much easier. Contact RLH for additional details: Flue Opening www.chim-flex.com © Travis Industries 100-01259 4150520...
  • Page 12: Surround Panel Installation

    When installing the panel, route the wires through the notch on the bottom of the panel (either side). Face Installation There are several face options available for this fireplace insert. Refer to the instructions included with your face. © Travis Industries 100-01259 4150520...
  • Page 13: Re-Routing The Electrical Cord To The Left Side

    Cord Re-attach the strain relief to the left side (use pliers to compress the strain relief from the top and bottom while pushing it into the hole). Remove the button plug from the left side. © Travis Industries 100-01259 4150520...
  • Page 14: Insert With Positive Connection

    See the section providing the chimney "Insert Placement system with sufficient Block-off plate or Requirements" for draft. damper adapter minimum clearances and hearth required. Figure 7 © Travis Industries 100-01259 4150520...
  • Page 15: Operating Your Appliance

    Shut the air control down to low and allow the stove to cool before proceeding. Over-firing may lead to damage of plated surfaces. If any portion of the heater glows red, it is considered over-firing and will void the warranty. © Travis Industries 100-01259 4150520...
  • Page 16: Opening The Doors

    You can also open the door a small amount and let air enter the firebox. Opening the Doors Rotate the handle up. Swing the door open. Closing the Doors Rotate the handle down to secure Lift the handle and close the door. the door. © Travis Industries 100-01259 4150520...
  • Page 17: Bypass Operation

    When starting or re-loading, pull the bypass out.  During normal operation, push the bypass in. Use the included pull tool Bypass Pulled Out to operate the bypass rod Used for starting and re-loading Bypass Pushed In Used for normal operation © Travis Industries 100-01259 4150520...
  • Page 18: Starting A Fire

    When you light the newspaper this “top-down” fire will burn its way to the center, igniting the larger pieces. With some practice, this method should work for you. © Travis Industries 100-01259 4150520...
  • Page 19: Adjusting The Burn Rate

    The air control becomes hot during operation - use gloves or a tool to prevent burns. The air control may take several minutes to influence the burn rate. When making adjustments, you may wish to let the stove burn for 10 minutes to gauge performance. © Travis Industries 100-01259 4150520...
  • Page 20: Ash Removal

    © Travis Industries 100-01259...
  • Page 21: Blower Operation

    Normal Operating Sounds The steel may creak or click when the stove heats up and cools down - this is normal. Blower Sounds: The blower will make a slight "humm" as it pushes air through the stove. © Travis Industries 100-01259 4150520...
  • Page 22: Hints For Burning

    Wood Cutting and Storage Cut wood to length and Store the wood off the ground in a chop into quarters. covered area. Allow for airflow Air Flow around the wood to dry the wood. Air Flow Air Flow © Travis Industries 100-01259 4150520...
  • Page 23 Burning these materials may result in release of toxic fumes or render the heater ineffective and cause smoke. © Travis Industries 100-01259 4150520...
  • Page 24: Troubleshooting

    See the section "Door and Glass Inspection" on page 26 for details.  Check the ash bed for coals. Often, coals are still glowing under a slight bed of flyash. By raking these into a pile you can re-start your stove quickly. © Travis Industries 100-01259 4150520...
  • Page 25: Maintaining Your Appliance

    The ash acts as a mild abrasive. The glass will develop a very slight haze over time. This is normal and will not affect viewing of the fire. © Travis Industries 100-01259 4150520...
  • Page 26: Monthly Maintenance

    Excess creosote buildup may cause a chimney fire, that may result in property damage, injury, or death. Operating this appliance continually at a low burn rate (air starvation) or using green (un-seasoned) wood will increase the formation of creosote. © Travis Industries 100-01259 4150520...
  • Page 27: Yearly Maintenance

    Slight scaling or rusting of the metal is normal. Make sure the air tubes are secured correctly. Floor and Wall Firebricks - replace any severely damaged firebrick along the side or floor of the firebox. © Travis Industries 100-01259 4150520...
  • Page 28: Door Parts

    Blower and Electrical Parts ID # Description Part # ID # Description Part # Left Blower 228-10069 Right Blower 228-10070 (4) Blower Grommets w Spacers 250-00369 Rheostat 250-00302 Rhoestat Knob w Nut 250-00869 Power Cord 250-00316 Thermodisk 228-30050 © Travis Industries 100-01259 4150520...
  • Page 29: Firebox Parts

    Remove the bypass plate and damper assembly by pulling forward and leaning the front edge down. Remove the four rear bricks. Remove baffle front and baffle plate (rotate it forward). © Travis Industries 100-01259 4150520...
  • Page 30: Air Tube Removal And Replacement

    (you may wish to rotate the tube slightly). Second Tube = 25-7/8” Third Tube = 22-5/8” Back Tube = 19-3/8” Pivot the air tube downwards and slide it out of the air channel on the opposite side. © Travis Industries 100-01259 4150520...
  • Page 31: Brick Removal & Replacement

    Remove the floor bricks first. The side bricks are pinned in place by the floor firebrick. Clean the firebox prior to replacing the brick. Refer to the section "Baffle Removal" on page 29 for details on removing the baffle bricks. © Travis Industries 100-01259 4150520...
  • Page 32: Warranty

    TRAVIS INDUSTRIES, INC., 12521 Harbour Reach Drive, Mukilteo, WA 98275. TRAVIS INDUSTRIES, INC. warrants this appliance (appliance is defined as the equipment manufactured by Travis Industries, Inc.) to be defect-free in material and workmanship to the original purchaser from the date of purchase as follows: Check with your dealer in advance for any costs to you when arranging a warranty call.
  • Page 33: If Warranty Service Is Needed

    14. TRAVIS INDUSTRIES, INC. is free of liability for any damages caused by the appliance, as well as inconvenience expenses and materials. Incidental or consequential damages are not covered by this warranty. In some states, the exclusion of incidental or consequential damage may not apply.
  • Page 34: Listing Label

    CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT INSTALLATION AND RESTRICTIONS IN YOUR AREA. SUITABLE FOR USE IN FACTORY-BUILT (Z.C.) FIREPLACES AND MASONRY FIREPLACES. MODEL: SERIAL NO: FLUSH WOOD PLUS Report No. 100289794PRT-001 Certified for USA and Canada Control No. 4000515 CONFORMS TO UL STD 1482;...
  • Page 35: Listing Information

    Listing Information © Travis Industries 100-01259 4150520...
  • Page 36: Index

    Overnight Burn ............21 Paint (Touch-Up Paint) .......... 27 Paint Curing ............15 Re-Loading the Stove ........... 21 Safety Label ............34 Safety Precautions ..........4 Smell (from paint curing) ........15 Smoke Enters Room (Troubleshooting) ....23 © Travis Industries 100-01259 4150520...

This manual is also suitable for:

Flush wood

Table of Contents