Download Print this page

Power Supply; Electrical Shock Hazard - Frigidaire PLCF489CCG Installation Instructions Manual

40" dual fuel range with electric ovens and gas cooktop

Advertisement

Available languages

Available languages

Power
Supply
Cord Kit
Tile user is responsible for connecting tile power supply
cord to the connection block located behind the back
panel access cover.
This appliance may be connected by means of
permanent "hard wiring" (flexible armored or
nonmetallic
shielded copper cable), or by means of a
power supply cord kit. Use only a power supply cord kit
rated at 125/250 volts minimum, 40 amperes minimum
and marked for use with ranges. See chart (below) for
cord kit connection opening size and rating information.
Cord must have either 3 or 4 conductors.
For mobile homes, new installations, recreational
vehicles, or areas where local codes do not permit
grounding through neutral, a 4 conductor power supply
cord kit rated at 125/250 volts minimum, 40 amperes
and marked for use with ranges should be used (see
Figure 4).
Terminals on end of wires must either be closed loop or
open-end spade lugs with upturned ends. Cord must
have strain relief clamp.
Risk of fire or electrical
shock exists if
an incorrect
size range cord kit is used, if the
Installation
Instructions
are not followed,
or [f the
strain relief
bracket
is discarded,
Range Connection
Opening
Size Chart
Refer to chart below for proper range connection
opening size
and power supply cord kit ampere rating information
See serial
plate on range for kilowatt
rating data.
Range Kilowatt
Rating
(See Serial Plate on Range)
I20/240 Volts
120/208 Volts
0-16.5 kW
0 -12,5 kW
I6,6-22.5kW
12.6-18,5kW
Minimum
Diameter (inches) of Range
Cord kit
Connection
Opening
Ampere
Direct
Rating
Cord Kit
Connection
40 Amp
1-:_/8 in.
1-I/8 in,
50 Amp
1-3/8 in.
1-3/8 in
NOTE: Dual-fuel range is shipped from factory with
1 1/8" dia. hole as shown in figure 3. If a larger hole
is required, punch out the knockout.
3-Wire Powe_
Supply Cord Kit
3-Wire
Wall
Receptacle
Figure 1
Electrical
Connection
to the Range
This appliance is manufactured with the neutral terminal
connected to the range.
While connecting
range, do not
loosen the nuts which secure the terminal
block to
the range. Electrical
failure
or loss of electrical
connection may occur.
Note: Refer to the wiring diagram at the end of this
manual.
Electrical
Shock Hazard
• Electrical
ground
is required
on this appliance.
Do not connect
to the electrical
supply
until
appliance
is permanently
grounded.
• Disconnect
power
to the circuit
breaker or fuse
box before
making the electrical
connection.
This appliance
must be connected
to a
grounded,
metallic,
permanent
wiring
system,
or a grounding
connector
should
be connected
to the grounding
termina[
or wire tead on the
appliance.
• Do not use the gas supply line for grounding
the appliance.
Failure to do any of the above could result in a
fire, personal
injury or electrical
shock.
Three
Conductor
Wire
Connection
to Range
(The 3<:onductor cord or (:able must be replaced with a
4<onductor
cord or cable where grounding through the
neutral conductor is prohibited in new installations,
mobile homes, recreational vehicles or in other areas
where local codes do not permit neutral grounding)
If local codes permit connection of the frame grounding
conductor to the neutral wire of the copper power supply
cord (see Figure 3):
1. Remove the 3 screws at the lower end of tile rear
wire cover, then bend tile lower end of the rear wire
cover (access
cover) upward
to expose range
terminal
connection
block (see
Figure 2).
_ea r wi re
access cover
Pressure
regulator
location
Figure
2

Advertisement

loading

This manual is also suitable for:

Plcf489ccePlcf489ccdPlcf489ccf