Power Supply Cord Kit (U.S.A.)
The user is responsible for connecting the power supply
cord to the connection block located behind the back
panel access cover.
This appliance may be connected by means of
permanent "hard wiring";
flexible armored or
nonmetallic shielded copper cable (when local code
allow it) or by means of a power supply cord kit. See
chart (on next page) for the minimum wire size (general
UL listing, local code may differ).
Appliance Rating Watts
Minimum Conductor Size, AWG
120V / 208V
L1 and L2
Neutral
Ground
Conductors
Conductor
Conductor
0-3120
16
16
14
3121-3900
16
16
12
3901-4160
14
16
12
4161- 5200
14
16
10
5201- 5570
12
16
10
5571-7430
12
14
10
7431-7800
12
12
10
7801-12500
10
12
10
12501-14500
8
12
10
Appliance Rating Watts
Minimum Conductor Size, AWG
L1 and L2
Neutral
Ground
120V/240V
Conductors Conductor Conductor
0-3600
16
16
14
3601-4500
16
16
12
4501-4800
14
16
12
4801-6000
14
16
10
6001-6425
12
16
10
6426-8749
12
12
10
8750-14500
10
12
10
14501-16500
10
10
10
16501-24000
8
10
8
Refer to chart below for proper range connection opening size and power
supply cord kit ampere rating information. See sedal plate on appliance for
kilowatt rating data.
See serial Plate on the
Appliance
for KW Rating
120/240 Voks
120/208
Voks
O-8.7kw
O-78kw
8.8-
16.5kw
7.9-
12.5kw
I6.6-
22.5 kw
I2.6-
18.5 kw
Cord Kit
Ampere
Rating
30 Amp
40 Amp
50 Amp
Diameter (inches (cm)) of
Appliance
Connection
Opening
Direct
Cold Kit
Connection
11/8
(2.g)
7/8(2.2)
13/8
(3.5)
11/8
(29)
1 318 (3.5)
1 3/8 (35)
Do not loosen the nuts which secure
the factory-installed
range wiring
to terminal
block
while
connecting
range. Electrical
failure
or loss of
electrical
connection
may occur.
[]Factory
Connected
Power
Supply
Cord
(Canada
only)
This range is equipped with a factory-connected
power
cord (see Figure 2). Cord must be connected to a
grounded 120/240 volt or 120/208 volt range outlet. If
not outlet is available, have one installed by a qualified
electrician.
NOTE: Electric Slide-in Range is shipped from factory
with 1 1/8" (2.9 cm) dia. hole as shown on figure 4. If a
larger hole is required, punch out the knockout.
Risk of fire or electrical
shock exists if
an incorrect
size range cord kit is used, the
Installation
Instructions
are not followed,
or the
strain relief
bracket
is discarded.
For mobile homes, new installations or recreational
vehicles, use only a power supply kit designed for a
range at 125V/250V 40A. Cord must have either 3
(when local code permits grounding through neutral) or 4
conductors. Terminal on end of wires must be either
closed loop or open spade lug with upturned ends. Cord
must have strain-releif clamp. See chart for the minimum
wire size (general UL listing,
local code may differ).
Canada Style
Figure 2
Electrical Shock Hazard
• Electrical ground
is required
on this appliance.
• Do not connect
to the electrical
supply until
appliance
is permanently
grounded.
• Disconnect
power to the circuit
breaker
or fuse
box before
making the electrical
connection.
• This appliance
must be connected
to a
grounded,
metallic,
permanent
wiring
system,
or a grounding
connector
should
be connected
to the grounding
terminal
or wire lead on the
appliance.
Failure to do any of the above could result in a
fire, personal injury or electrical shock.