Tightenall connectionsif necessary to prevent g as
leakage in thecooktop or supply line.
Check alignmentof valvesafterconnecting t he
cooktop to thegassupply to besurethemanifold pipe
hasnot beenmoved.
Disconnect t he rangeandits individualshutoff
valvefromthegassupply pipingsystem duringany
pressure t estingof thesystem attestpressures greater
than1/2psig(3.5kPa or 14" watercolumn).
LP/Propane G asConversion
This appliance canbeused withNatural Gas or Propane
Gas. I t isshipped f romthefactory forusewithnatural gas.
If youwishto convert yourrange for use withLP/Propane
gas, u sethesupplied f ixedorifices; theyarecontained i n a
special bagalong withinstructions marked "FOR LP/
PROPANE
GAS CONVERSION",
locatedon the backof
the range,doseto the appliance regulatorvalve.
The conversion mustbeperformed b ya qualified installer,
LP supplier o rservice t echnician i naccordance withthe
installation i nstructions furnished w iththisrange andall
codes a ndrequirements ofalllocal c odes a nd
requirements. Failure t ofollowinstructions could result i n
serious i njury or property d amage. The qualified agency
performing t hisworkassumes responsibility forthe
conversion.
Moving
the Appliance
for
Servicing
and Cleaning
Turn off the range line fuse or circuit breakers at the
main power source, and turn off the manual gas shut-off
valve. Make sure the range is cold. Remove the service
drawer and open the oven door. Lift the range at the
front and slide it out of the cut-out opening without
creating undue strain on the flexible gas conduit.
tsolate
the range
from
the gas supply
piping
system
by closing
its individual
manual
shutoff
valve during
any
pressure testing
of the gas supply piping
system at test
pressures equal to or less than
1/2 psig (3.5kPa
or 14"
water
column).
Make sure not to pinch the flexible gas conduit at the
back of the range when replacing the unit into the cut-
out opening. Replace the drawer, close the door and
switch on the electrical power and gas to the range.
If the pressure regulator is connected to rigid piping, tile
regulator must be disconnected before moving the
appliance.
Reassemble
in reverse order (see figure
9).
Failure to make the appropriate conversion
can result in personal injury and property damage.
_Any
additions, changes or conversions
required in order for this appliance to satisfactorily meet
the application needs must be made by an authorized
Sears Service Center, Distributor or Qualified Agency.