Installation Instructions; Power Supply Cord Kit (U.s.a.); Factory Connected Power Supply Cord (Canada Only) - Frigidaire GLCS376ABA Installation Instructions Manual

30" dual fuel slide-in range
Hide thumbs Also See for GLCS376ABA:
Table of Contents

Advertisement

Available languages

Available languages

30" DUAL FUEL SLIDE-IN RANGE
(Models with an Electric O
INSTALLATION INSTRUCTIONS
yen and a Gas Cooktop)
I WARNING
CANADA ONLY : This appliance is
equipped with a 4-prong grounding plug for your
protection against shock hazard, and should be
plugged directly into a properly grounded
receptacle. Do not cut or remove the ground prong
from this plug.
FOR MODELS WITH SELF-CLEAN FEATURE:
• Remove broiler pan, food and other utensils
before self-cleaning the oven. Wipe up excess
spillage. Follow the precleaning instructions in the Use
and Care Guide.
1. Power Supply Cord Kit (U.S.A.)
The user is responsible for connecting the power supply
cord to the connection block located behind the back
panel access cover.
This appliance may be connected by means of
permanent "hard wiring" (flexible armored or
nonmetallic shielded copper cable), or by means of a
power supply cord kit. Only a power supply cord kit
rated at 125/250 volts minimum, 40 amperes and
marked for use with ranges shall be used. See chart
(below) for cord kit connection opening size rating
information. Cord must have either 3 or 4 conductors.
For mobile home installation, or areas where local codes
do not permit grounding through neutral, a 4 conductor
power supply cord kit rated at 125/250 volts minimum,
40 amperes and marked for use with ranges should be
used (see Figure 5).
Terminals on end of wires must be either closed loop or
open-end spade lugs with upturned ends. Cord must
have strain-relief clamp.
See below for 3 or 4 conductor wire connection.
Range Connection Opening Size Chart
Refer to chart below for range connection opening size and power
supply cord kit ampere rating information. See serial plate on range
for kilowatt rating data.
See Serial Plate on Range for
Se
S
Rating
Kw
Cord Kit
Ampere
Rating
Diameter (inches (cm)) of
Range Connection
Opening
120/240 Volts
120/208 Volts
Cord Kit
Direct
Connection
0-16.5 Kw
16.6-22.5 Kw
0-12.5 Kw
12.6-18.5 Kw
40 Amp.
50 Amp.
13/8(3.5)
1 3/8(3.5)
1 1/8 (2.9)
1 3/8(3.5)
NOTE: Dual fuel Slide-in Range is shipped from factory
with 1 1/8" (2.9 cm) dia. hole as shown on figure 4. If a
larger hole is required, punch out the knockout.
j
WARNING
Risk of fire or electrical shock exists if
an incorrect size range cord kit is used, the
Installation Instructions are not followed, or the
strain relief bracket is discarded.
QCAUTION
U.S.A.
Figure 1
Do not loosen the nuts which secure
the factory-installed range wiring to terminal block
while connecting range. Electrical failure or loss of
electrical connection may occur.
2. Factory Connected Power Supply
Cord (Canada only)
This range is equipped with a factory-connected power
cord (see Figure 2). Cord must be connected to a
grounded 120/240 volt or 120/208 volt range outlet. If
not outlet is available, have one installed by a qualified
electrician.
Canada Style
Figure 2
àWARNING
Electrical Shock Hazard
• Electrical ground is required on this appliance.
• Do not connect to the electrical supply until
appliance is permanently grounded.
• Disconnect power to the circuit breaker or fuse
box before making the electrical connection.
• This appliance must be connected to a
grounded, metallic, permanent wiring system,
or a grounding connector should be connected
to the grounding terminal or wire lead on the
appliance.
• Do not use the gas supply line for grounding
the appliance.
Failure to do any of the above could result in a
fire, personal injury or electrical shock.
3

Advertisement

Table of Contents
loading