10. Check
Operation
Refer to the Owner's Guide packaged with the range for
operating instructions and for care and cleaning of your
range.
[Iri_'_!_TP/T_Do not touch the elements or burners.
They may be hot enough to cause burns.
Remove all packaging from the oven before testing.
1.
Install Burner Bases and Burner Caps
This range is equipped with sealed burners as shown
(see Figure 12).
Burner Cap
Burner Base
Burner Pan
Gas Opening
To check for proper lighting:
A.
Push in and turn a surface burner knob to the
LITE position.
You will hear the igniter sparking.
B. The surface burner should light when gas is
available to the top burner.
Each burner should
light within four (4) seconds in normal operation
after air has been purged from supply lines.
Visually check that burner has lit.
C. Once the burner lights, the control knob should
be rotated out of the LITE position.
There are separate ignition devices for each burner.
Try each knob separately until all burner valves have
been checked.
,
Adjust the "LOW" Setting of Surface Burner
Valves (see Figure 13)
A.
Push in and turn each control to LITE until burner
ignites.
B. _Q_turn
knob to LOWEST POSITION.
C.
If burner goes out, readjust valve as follows:
Reset control to OFF. Remove the surface burner
control knob, insert a thin-bladed screw driver
into the hollow valve stem and engage the
slotted screw inside. Flame size can be
increased or decreased with the turn of the
screw. Adjust flame until you can quickly turn
knob from LITEto LOWEST POSITION without
extinguishing
the flame.
Flame should be as
small as possible without
going out.
Electrode
Figure 12
A.
Unpack burner bases and burner caps.
B.
Place burner bases over each gas opening.
C.
Make sure the burner is properly aligned and
leveled. Place burner caps over appropriate
burner bases.
NOTE: There are no burner adjustments necessary on
this range.
2.
Turn on Electrical
Power
and Open
Main
Shutoff
Gas Valve
,
Check the Igniters
Operation of electric igniters should be checked after
range and supply line connectors have been carefully
checked for leaks and range has been connected to
electric power.
Figure 13
10