CANADA
ONLY : This appliance
is
equipped
with
a 4-prong
grounding
plug for your
protection
against
shock hazard,
and should
be
plugged
directly
into a properly
grounded
receptacle.
Do not cut or remove
the ground
prong
from this plug.
FOR MODELS WITH SELF-CLEAN FEATURE:
• Remove broiler pan, food and other utensils
before self-cleaning the oven. Wipe up excess
spillage. Follow the precleaning instructions in the Use
and Care Guide.
1. Power
Supply
Cord Kit (U.S.A.)
The user is responsible for connecting the power supply
cord to the connection
block located behind the back
panel access cover.
This appliance may be connected by means of
permanent "hard wiring" (flexible armored or
nonmetallic shielded copper cable), or by means of a
power supply cord kit. Only a power supply cord kit
rated at 125/250 volts minimum, 40 amperes and
marked for use with ranges shall be used. See chart
(below) for cord kit connection opening size rating
information.
Cord must have either 3 or 4 conductors.
For mobile homes, new installations, recreational
vehicles, or areas where local codes do not permit
grounding through neutral, a 4 conductor power supply
cord kit rated at 125/250 volts minimum, 40 amperes
and marked for use with ranges should be used (see
Figure 5).
Terminals on end of wires must be either closed loop or
open-end spade lugs with upturned ends. Cord must
have strain-relief clamp.
See below for 3 or 4 conductor wire connection.
Refer to chart below for range connection opening size and power
supply cord kit ampere rating information.
See serial plate on range
for kilowatt rating data.
See Serial Plate on Range for
Kw Rating
Cord Kit
Ampere
120/208 Volts
Rating
120/240 Volts
0-16.5 Kw
16.6-22.5 Kw
0-12.5 Kw
40 Amp.
12.6-18.5 Kw
50 Amp.
Diameter (inches (cm)) of
Range Connection
Opening
Direct
Cord Kit
Connection
1 3/8 (3.5)
1 1/8 (2.9)
1 3/8 (3.5)
1 3/8 (3.5)
NOTE: Dual fuel Slide-in Range is shipped from factory
with 1 1/8" (2.9 cm) dia. hole as shown on figure 4. If a
larger hole is required, punch out the knockout.
Risk of fire or electrical
shock exists if
an incorrect
size range cord kit is used, the
Installation
Instructions
are not followed,
or the
strain
relief
bracket
is discarded.
Do not loosen the nuts which secure
the factory-installed
range wiring to terminal
block
while connecting range.
Electrical failure or loss of
electrical connection may occur.
2. Factory
Connected
Power
Supply
Cord (Canada
only)
This range is equipped with a factory-connected
power
cord (see Figure 2). Cord must be connected to a
grounded 120/240 volt or 120/208 volt range outlet.
If
not outlet is available, have one installed by a qualified
electrician.
Canada Style
Figure 2
Electrical
Shock
Hazard
• Electrical ground is required on this appliance.
• Do not connect to the electrical supply until
appliance is permanently
grounded.
• Disconnect power to the circuit breaker or fuse
box before making the electrical connection.
• This appliance must be connected to a
grounded, metallic, permanent wiring system,
or a grounding
connector should be connected
to the grounding
terminal or wire lead on the
appliance.
• Do not use the gas supply line for grounding
the appliance.
Failure to do any of the above could result in a
fire, personal injury
or electrical shock.
3