11.4 Current Draw and Thermal Dissipation specifications

Table 11.4 contains data on measured current consumption and calculated heat dissipation for four operating
conditions: i) Power on, no signal; ii) Normal operation (1/8 of rated power); iii) Heavy duty operation (1/4 rated
power – see Note 3 at foot of table); iv) 20 kHz sine wave.
Level
Load
Standby, with remote power off.
Powered on, idling.
Pink noise (1/8
16 Ω / Ch.
rated power)
8 Ω / Ch.
4 Ω / Ch.
2.67 Ω / Ch.
2 Ω / Ch.
Pink noise (1/4
16 Ω / Ch.
rated power)
8 Ω / Ch.
*3)
4 Ω / Ch.
2.67 Ω / Ch.
2 Ω / Ch.
sine Wave
16 Ω / Ch.
20 kHz
16 Ω / Ch.
Mains connector - 230 V CE version / 230V ETL version / 115 V ETL version
*1) The amplifi er section's PSU operates as a non-resistive load, so the calculation "Volts x Amps = Watts" would not be correct. Instead, measured
and specifi ed here is what is known as the "Active Power" of the amplifi er section providing useful, real-world values of power consumption and
heat dissipation.
*2) Current draw fi gures measured at 230 V. 115 V fi gures are converted from 230 V fi gures.
*3) Figures measured at maximum power before amplifi er protection and limiter features are engaged. Typically this is between 1/4 and 1/3 of rated
power. Note that the maximum power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not
be tripped even if operation is in excess of maximum ratings.
Table 11.4: PLM 10000Q Current Draw and Thermal Dissipation specifications
PLM is a trademark of Lab.gruppen AB. Dolby, Lake, and the double-D symbol are registered trademarks of Dolby Laboratories.
PLM 10000Q
Line Current *2)
Rated power
120 VAC
230 VAC
Amp (I)
660
x4
9.3
4.8
1300
x4
16.3
8.5
2300
x4
25.2
13.2
2700
x4
31.3
16.4
2350
x4
29.2
15.2
660
x4
14.7
7.7
1300
x4
26.0
13.6
2300
x4
45.8
23.9
2700
x4
52.5
27.4
2350
x4
51,0
26.6
1
x4
2.7
1.4
0.25
x4
2.5
1.3
Copyright © 2007-2008 Lab.gruppen AB. All rights reserved.
Watt *1)
In
Out
Dissipated
4.8
0
4.8
145
0
145
Watt
687
330
357
1250
650
600
2014
1150
864
2553
1350
1203
2341
1175
1166
1098
660
438
2049
1300
749
3746
2300
1446
4420
2700
1720
4179
2350
1829
160
4
156
149
1
148
32 A, Neutrik PowerCon Twist lock
PLM Series Operation Manual 55
APPENDIX 11
Thermal Dissipation
BTU/hr
kCal/hr
16
4
496
125
1218
307
2048
516
2949
743
4106
1034
3980
1003
1495
377
2556
644
4935
1243
5870
1479
6242
1573
532
134
505
127

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plm 10000q

Table of Contents