Firmware Upgrades Using The Dolby Lake Controller Plm Edition - Lab.gruppen PLM Series Operation Manual

Plm series powered loudspeaker management systems
Hide thumbs Also See for PLM Series:
Table of Contents

Advertisement

Figure 12.7.1e: Firmware update utility completion page
9.
Cycle the power of each PLM by turning the
power switch off, and then either removing the
PowerCon connector from the rear of each PLM
or switching off all power to the PLM racks at
source. Then reconnect the power and switch
the PLMs back on. The mains power must be
cycled in order for the firmware upgrade to take
effect.
10.
If the new firmware includes upgrades for the
amplifier, or the front panel functions, these
upgrades will be initialized automatically.
Activity and progress will be indicated on the
front panel. After an upgrade of the amplifier
firmware, the unit will reboot automatically.
11.
The current user settings in the PLM
are retained during the firmware
upgrade. However, as a precaution,
settings can be stored either as a
frame preset in the unit or as a system
file on the PC.
12.
On the PC, tap OK, then tap Exit to quit the
Firmware Update Utility.
APPLICATION GUIDE 12
12.7.2 Firmware upgrades using the Dolby
Lake Controller PLM Edition
The PLM firmware may also be upgraded from
the DLC PLM Edition software application. It is
recommended that this method is used only for
upgrading small numbers of PLMs. The Firmware
Update Utility provides a faster upgrade process for
large networks.
To upgrade using the DLC PLM Edition software:
1.
Install the latest version of the DLC PLM Edition
software. Power on all PLMs and connect to
the PC using a wired network.
2.
Launch the Controller in the normal way.
3.
Tap
Modules and drag an old module from
the Modules scrolling bar into the work area.
The module will flash indicating that the PLM
it relates to has old firmware and a warning
message will appear.
4.
Read the warning message and tap
5.
Place all old firmware modules in the work area,
then tap Home.
12.7.2: Firmware updating via the DLC PLM Edition
software
6.
Tap the flashing
Update Firmware button.
7.
Read the onscreen warning message, tapping
Yes to proceed.
8.
When all Processors have been updated,
cycle the power of each PLM by turning the
power switch off, and then either removing
the PowerCon connector from the rear of each
PLM or switching off all power to the PLM
racks at source. Then reconnect the power and
switch the PLMs back on. It is very important to
cycle the mains power in order for the firmware
upgrade to take effect.
PLM Series Operation Manual 71
Ok.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plm 10000q

Table of Contents