Maintenance; Factory Default Settings - Lab.gruppen PLM Series Operation Manual

Plm series powered loudspeaker management systems
Hide thumbs Also See for PLM Series:
Table of Contents

Advertisement

11 APPENDIX

11.2 Maintenance

During normal operation your PLM will provide
trouble-free service. The main user maintenance is
to periodically clean the dust filters behind the front
grilles. The two grilles can be removed by undoing the
knurled-head screws, and the foam filter elements
then withdrawn. They are best cleaned with a hand-
held vacuum cleaner.
If the LCD display needs cleaning, use a soft cloth
only. Do NOT use solvent cleaners of any kind as
they may attack the plastic.
In some extreme cases it may be necessary to clean
the inside of the PLM. This procedure should only
be carried out by qualified service personnel. This
may be necessary if the PLM has had prolonged
operation in an extreme environment such as one
where "cracked oil" smoke machines are in use.
If you are using your PLM in such a heavy duty
application, it is recommended to have it serviced
every 3 years as a purely preventative measure.
54 PLM Series Operation Manual

11.3 Factory Default settings

Modules:
Modules:
2 x 2 Aux
Levels:
Unity (all gain adjustments)
EQ:
All EQ flat
Polarity:
In phase
MaxRMS:
20 dB
MaxPeak:
21 dB
Input mutes
On
Autoselect
On
Input sensitivity:
+26 dBu
Dante
Disabled.
AES/EBU
Terminated
IsoFloat
Enabled
ISVPL:
153 V
Amp Gain:
35 dB
Router 1
AES 1 set as Priority 1
Analog 1 set as Priority 4
Router 2
AES 2 set as Priority 1
Analog 2 set as Priority 4
Frame/Power Output stage
Attenuation:
0 dB
Polarity:
In phase.
Mute:
Unmuted
Load Model:
Not loaded

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plm 10000q

Table of Contents