Backguard Installation; Electrical / Gas Connections - Jenn-Air PRAD3022 Installation Manual

Professional 30", 36" dual fuel range
Table of Contents

Advertisement

BACKGUARD INSTALLATION
BACKGUARD
KITS:
Model PRD3030 is shipped standard with a 9" Low backguard.
High Shelf backguards, Island Trims and
the Low Back for Model PRD3630 must be ordered
separately.
Specific instructions
for installation
of
the High Shelf backguard,
Low backguard
or Island Trim Backguard can be found packaged with the
backguard.
All backguards
or island trims must be installed
on the range before the unit is pushed
into the cabinet.
A backguard
must be installed
when there is less than a 12" clearance
between
combustibles
and the back of the range (above the cooking
surface). See fig. 12. Refer to page 3 for
backguard
model numbers.
ELECTRICAL / GAS CONNECTIONS
ELECTRICAL CONNECTIONS
PRD3630
model
Always disconnect
electric supply cord from the wall outlet or service disconnect
before servicing
this
appliance.
Observe all governing
codes and ordinances
when grounding,
in absence of which,observe
National Electrical Code ANSI / NFPA No. 70-I 990. The electrical
supply must be a 120/240 volt, 3 wire
(plus ground)
60 Hz single phase, S0 AMP circuit. The power receptacle must be a NEMA 14-50 device
to accept the four prong plug supplied
with the
unit.The
receptacle should be located within
the
area shown in fig.9 page 9.
PRD3030
MODEL
The electrical
supply
must be a 120/240 volt, 3
wire (plus ground),
60 Hz, 30 AMP circuit.
The
power receptacle
must be a NEMA 14-50 device
to accept the four prong plug supplied
with the
unit. The receptacle should be located within the
area shown in fig. 10, page 10.
_-
Electrical Supply
--.
j
\
_-..
NEMA 14-50
Receptacle
Fig. 13
12