Page 1
Professional30"and36" IS]ENN-AIR DualFuel RangeModels 400WEST FOURTH STREET, NORTH"NEWTON, IA50208 0®® Retain this manual for future reference. 17665 REVC 04/2004...
Page 2
A MESSAGE TO OUR CUSTOMERS For your convenience, product questions can be answered by Jenn-Air Customer Assistance 1-800dENNAIR (1-800-536-6247) 1-800-688-2080 (U.S.TTY for hearing or speech impaired) Mon. - FrL,8 am - 8 pm Eastern Time Internet: www.jennair.com Maytag Services sm Attn: CAIRR Center RO.
PRD3030, which is shipped standard with a 9" low backguard. See figure below for sizes and model numbers. 22" High Shelf Backguard option Model PRAD3022 (30") Model PRAD3622 (36") 12" Lowback option Model PRAD3612 9" Lowback (30 models only) Island Trim Model PRAD3001 (30")
UNPACKING AND HANDLING MOVING AND PLACING THE RANGE The ranges have shipping weights varying from 420 Ibs. to 630 Ibs. less approx. SO Ibs. after removal of packing material. It is recommended that the door, grates, and front kick panel be removed to facilitate handling.
Page 7
UNPACKING AND HANDLING Remove the kick panel by removing two screws at the top and pulling forward. The range is held to the skid by two bolts in the front behind the kick panel, Range Must (fig. 3) and two L-brackets located on the bottom...
VENTILATION REQUIREMENTS A suitable exhaust hood must be installed above the range. The following chart indicates minimum blower capacity recommended for hood ventilation. VENTILATION STANDARD COUNTER ISLAND UNIT INSTALLATION INSTALLATION RECOMMENDATIONS RECOMMENDATIONS HOOD (24" Deep x Unit Width) (30" Deep x 36" at Bottom) BLOWER 36"...
INSTALLING ANTI-TIP DEVICE All ranges must have an antFtip device (2) Wood Screws into correctly installed as per the following Back Wall (ALL Installations) instructions. If you pull the range out (2)Small Holes for from the wall for any reason, make sure Wood Installations that the device is properly...
CABINET PREPARATION 1) The range is a free standing unit. If the unit is to be placed adjacent to cabinets, the clearances shown in fig.9 (PRD3630) & fig. 10 (PRD3030) are required. The same clearances apply to island installations. 2) The range can be placed in various positions with respect to the cabinet front, with the front either flush or projecting, depending...
Page 11
CABINET PREPARATION 35-3/4"max,forlevelcounter, 37"max,with range levelinglegs fullyextended A Asdefined i n the"National Fuel Gas C ode" (ANSI Z223,% lastest edition), The horizontal surfaces o f therangetop (cooktop) trimmustnot bebelowcountertop l evel. Fig. 10 PRD3030 Model Only Manual Shut-Off Valve m ustbe Easily Accessible 2"Maximum Electrical Supply...
Page 12
[CABINET PREPARATION ISLAND INSTALLATION: STANDARD INSTALLATION: 12"Min.to Combustibles/X without backguard High Shelf Backguard 36"Min.to (bim."A") Combustibles _. _/Island Trim Low Backguard (Dim."B") 0" Clearance _E_IIIIIIIIIIIIIIIIIIII _" A Asdefined in the "National FuelGasCode" (ANSIZ223.1,Latest Edition). Thehorizontal surfaces of the rangetop (cooktop) trim must not be below countertop level, Fig.
BACKGUARD INSTALLATION BACKGUARD KITS: Model PRD3030 is shipped standard with a 9" Low backguard. High Shelf backguards, Island Trims and the Low Back for Model PRD3630 must be ordered separately. Specific instructions for installation the High Shelf backguard, Low backguard or Island Trim Backguard can be found packaged with the backguard.
Page 14
ELECTRICAL / GAS CONNECTIONS RECOMMENDED GROUNDING METHOD This appliance is factory equipped with a power supply cord with a four-prong grounding plug. must be plugged into a mating grounding, type receptacle, connected to a correctly polarized 120/240 volt circuit. If the circuit does not have a grounding type receptacle, it is the responsibility...
HOOK-UP TO GAS SUPPLY CAUTION: The appliance must be isolated from the building's gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than I/2 psig (3.SkPa.).
[INSTALLER FINAL CHECKLIST GENERAL FI Placement of unit. FI Specified clearance maintained to cabinet surfaces. r] Unit Level - front to back, side to side. FI All packaging material and tie straps removed, drip pans clean and empty. FI Backguard attached if there is less than 12"...
WARRANTY 1 FULL ONE YEAR WARRANTY - PARTSAND LABOR For one (I) year from the original retail purchase date, any part which fails in normal home use will be repaired or replaced free of charge. Limited Warranties - Parts Only Second Year - After the first year from the original purchase date, parts which fail in normal home use will be repaired or replaced free of charge for the part itself, with the owner paying all other costs,...
Page 22
Proof of purchase (sales receipt). [] User's guides, service manuals and parts information are available from Maytag Services% Jenn-Air Customer Assistance. 1-800-JENNAIR (1-800-536-6247) 1-800-688-2080 (U.S.TTY for hearing or speech impaired) Mon.- Fri.,8 am - 8 pm Eastern Time Intemet: www.jennaincom...
Page 24
Before you begin, read these instructions completely and carefully. WARNING If the information tn these instructions is not followed exactly, firet explosion production of carbon monoxide may result_causing property damage, personal injury or loss of life. This conversion kit must be installed bya qualified service agency in accordance with the manufacturer's instructions.
Page 25
IMPORTANT: Disconnect the range and the individual shut-off valve from the gas supply piping system during ony pressure testing of that system at test pressures greater than 1/2 psig. isolate the range from the gas supply piping system by closing the individual manual shut-off...
Page 26
TOREPLACE THE VALVE BYPASS J ETS: i. Remove control knobs from the valve shafts and thermostat. 2. Remove the two screws that attach valve panel to thermostat bracket (located behind thermostat knob), 3. Remove the four mounting screws from the corners of the valve par_e! (T-15 Torx Screw).
Page 27
STEP 4 CHECK FOR LEAKS ,/'fX, WARNING Check for leaks before attempting to light the burners or use the oven. • Check to be sure all controls are in the OFF position, III Turn on the gas supply at the shut-off valve.
Page 28
Burner Adjustment There is no air shutter adjustment, etc, on this burner. SINGLE FLOW DUAL FLOW Burner Cap Simmer Flame High to Low Flame STEP 6 COMPLETE AND ADHERE CONVERSION LABEL TO THE REAR OF THE RANGE Complete the required information on the Conversion Label.
Page 29
JENN-AIR 1-800-JENNAIR (1-800-536-6247) 1-800-688-2080 (U.S.TTY for hearing or speech impaired) Mon.- Fri., 8 am - 8 pm Eastern Time Internet: www.jennaincom 1-800-688-2080 (ATS Etats-Unis pour les malentendants et les handicap6s de la parole) du lundi au vendredi, de 8 h O0 _ 20 h 00, heure de I'est Internet: www.jennair.com...
Need help?
Do you have a question about the PRAD3022 and is the answer not in the manual?