Electrical Shock Hazard
Plug into a grounded 3-prong outlet.
Do not remove ground prong.
Do not use an adapter.
Failure to follow these instructions can result
in death, fire, or electrical shock.
If codes permit and a separate ground wire is used, it
is recommended that a qualified electrician determine
that the ground path is adequate.
Do Not ground to a gas pipe.
Check with a qualified electrician if you are not sure
range is properly grounded.
A 120-volt, 60-Hz, AC-only, 10-ampere, fused electrical
supply is required. A time-delay fuse or circuit breaker
is recommended. It is recommended that a separate
circuit serving only this appliance be provided.
Electronic ignition systems operate within wide
voltage limits, but proper grounding and polarity are
necessary. In addition to checking that the outlet is
correctly grounded, the outlet must be checked by a
qualified electrician to see if it is wired with correct
polarity.
A wiring diagram is included on the back of
the range.
See "Cabinet dimensions/requirements,"
Pages 6-7,
for recommended location of electrical outlet.
Peligro de choque eldctrico
Ench_felo en un tomacorriente
mural de
conexibn a tierra con tres terminales.
No quite el terminal para conexibn a tierra.
No use adaptador.
No seguir estas instrucciones
puede
ocasionar la muerte, un incendio o un choque
eldctrico.
Si los codigos Io permiten y se usa un alambre de
puesta a tierra separado0se recomienda que un
electricista calificado determine si el trayecto de la
puesta a tierra es adecuado.
No conecte la unidad a tierra a una tuberia de gas,
Consulte con un electricista calificado si no esta
seguro de que la cocinatenga la debida conexion a
tierra.
Se requiere un suministro electrico de 120 voltios, 60
Hz, s61ode CA, de 10 amperes, protegido por fusibles.
Se recomienda usar un fusible con retardo o un
interruptor de circuito. Se recomienda usar un circuito
separado que sirva solamente a este artefacto.
Los sistemas de ignici6n electr6nica funcionan dentro
de amplios limites de voltaje, pero son necesarias la
puesta a tierra y la polaridad adecuadas.
Ademas de verificar que el tomacorriente este
debidamente puesto a tierra, un electricista calificado
debe revisar el tomacorriente para determinar si esta
cableado con la polaridad correcta.
Se incluye un diagrama de cableado en la parte
trasera de esta cocina.
Para las recomendaciones de ubicaci6n del
tomacorriente, vea "Dimensiones/requisitos
del
gabinete" en la Paginas 6-7.
®
®
\
\
\
\
Recommended
ground method
For your personal safety, this range must be
grounded. This range is manufactured with a power
supply cord ® having a 3-prong ground plug ®. To
minimize possible shock hazard, the cord must be
plugged into a mating, 3-prong, ground-type
outlet ®, grounded in accordance with National
Electrical Code, ANSI/NFPA 70 -- latest edition* and
all local codes and ordinances.
Ifa mating outlet is not available, it isthe
responsibility and obligation of the customer to have a
properly polarized and grounded, 3-prong outlet
installed by a qualified electrician.
Copies of the standards listed may be obtained from:
* National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
Metodo recomendado de
puesta a tierra
Para su seguridad personal esta cocina debe tener
conexi6n de puesta a tierra. Esta cocina esta equipada
con un cord6n de alimentaci6n electrica @ provisto de
un enchufe ,de puesta a tierra con tres clavijas ®. Para
reducir al minimo el riesgo de choque, el cord6n debe
ser enchufado en un tomacorriente de puesta a tierra
con tres terminales ®, puesto a tierra de acuerdo con
el C6digo Electrico Nacional, ANSI/NFPA 70-_ltima
edici6n* y todos los c6digos y reglamentos locales.
Si no se dispone de un tomacorriente mural con tres
terminales adecuado, es responsabilidad y obligaci6n
del cliente hacer instalar por un electricista calificado
un tomacorriente mural con tres terminales
debidamente puesto a tierra.
Se poeden obtener copias de los est&ndares indicados de:
* National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents