User Operations

The following user operations are implemented through the front panel of the VSR or the VSR Keyboard
utility.

Recording (R)

To begin recording, press the record button on the front panel or press the R key on your keyboard. RECORD
will be indicated for three seconds, near the upper left hand corner of the output monitor. The unit always
starts recording at the end of the previously recorded data.
Recording will continue until:
The Stop button is pressed.
The disk is full (In No Overwrite and Overwrite Once modes). See
Mode
on page 39, for details regarding Disk Overwrite modes.
Normal Recording
The normal record speed is indicated on the output monitor, and can be altered using the Up/Down Record
Speed buttons, or page up/page down keys on your keyboard.
For information about altering the normal record speed from the menu system, see
Settings / Record Speed
The normal record speed can be altered while the unit is recording. The unit will continue recording while the
menu system is active.
Alarm Recording
An alarm condition is indicated in several ways:
With the word ALARM, displayed on the output monitor, near the upper left hand corner of the screen.
With the LED Alarm Indicators on the front panel of the unit.
With the internal buzzer (if activated in the menu system). For information about activating the
internal buzzer during alarms, see Main Menu / Alarms on
section of this manual.
By an external device, connected to the alarm output of the unit (if the unit is installed that way).
Disk Nearly Full Notification
A Disk Full. Recording has stopped message will appear on the output monitor to indicate that the unit has
stopped recording, because the disk is full and No Overwrite Mode is selected.
No Overwrite mode: The user must acknowledge the on-screen message by pressing the Enter button.
In this mode the VSR will not record over previously recorded data. To continue recording, the data must be
erased (or deleted) in the Advanced / Disk Maintenance menu.
Overwrite Once mode: The user must acknowledge the on-screen message by pressing the Enter button.
The unit will continue recording again when the user presses the Record button.
on page 34 of the Operator Programming section of this manual.
Advanced Menu / Disk Overwrite
Main Menu / Record
page 27
of the Operator programming