Electrical Connection - Travis Industries DVS FIREPLACE Owner's Manual

Built-in direct vent fireplace
Hide thumbs Also See for DVS FIREPLACE:
Table of Contents

Advertisement

Electrical Connection

!
Make sure the household breaker is shut off prior to working on any electrical lines.
!
The fireplace must be properly grounded in accordance with local codes (or ANSI/NFPA 70-1987)
¥
The electrical line must be 14 gauge, and supply 120 Volts at 60 Hz (2 Amps)
Feed the electrical line
through the strain
relief.
1 Remove the junction box cover at the right front corner of the fireplace near the base.
2 Feed the electrical line through the strain relief (use insulated Romex (¨) type wire).
3 Remove the wires from the junction box. Expose approximately 1/2" of metal wire from each line of
the electrical line. Use wire nuts to secure the wires together. Connect the green wire to the ground
wire (usually green), the white wire to the common wire (usually white), and black wire to the hot
wire (usually black).
NOTE :
If using a thermostat or remote control , route the wire through the junction box along with
the electrical line - see the section "Optional Equipment".
4 Push the wire connections into the junction box. Replace the cover plate.
5 Tighten the strain relief on to the outer insulation of the electrical line to secure.
I
NSTALLATION
Use wire nuts to connect the wires together. Push the
connections inside the junction box, and re-attach the cover
plate. Tighten the strain relief on to the outer insulation of the
electrical line to insure the line does not pull loose.
The junction box is located
in the right rear corner of
the fireplace. Remove the
junction box cover plate to
access the wires (use a
standard screwdriver).
(C
.)
ONT
- For Qualified Installers Only!
P
AGE
Run an electrical line to
a location at the right
front of the fireplace
23