TROUBLESHOOTING
Refer to
TAKING THE UNIT APART
the brush motor
Remove the base cover and recline the unit. Check the voltage going to the brush motor
by disconnecting the leads and reading the line voltage. Line voltage should be 100-150+
volts DC. If this voltage is present, the brush motor is defective.
Check Line Voltage
If the voltage is 0 at the brush motor, check voltage at the brush switch. Using the
grey/white wire as reference, the voltage when probing the top terminal on the switch
should be 100-150+ DC volts. If this voltage is present, the switch is bad.
Check Voltage at top terminal
Issued: September, 2005
© 2005 BISSELL Homecare, Inc.

BRUSH MOTOR WILL NOT TURN

-