VKI Technologies Eccellenza Pod Operation Manual page 33

Hide thumbs Also See for Eccellenza Pod:
Table of Contents

Advertisement

Operation Manual
MESSAGE DISPLAYED
Overheat Error
Power Saving Mode –
Press Start to Exit
Tank Not Heating Error
Temperature Probe
Error
Thermister Shorted
Error
Thermister Open Error
Water Level Error
Water Source Error
Whipper Error
CAUSE
The water tank is
overheating.
The machine is in Power
Saving Mode.
The hot water tank is not
heating.
The temperature probe is
not functioning correctly.
The thermister is not
functioning correctly.
The thermister is not
functioning correctly.
The water tank is
overfilling.
The water tank is not filling
with water.
An error has been detected
with the whipper.
POSSIBLE REMEDIES
• Check the temperature settings in the
set-up.
• The temperature probe may need to be
replaced.
• Press "
" (
) to exit Power Saving
START
Mode.
• Check the 15 amp fuse.
• Reset the thermal cut-off switch.
• Verify wiring to heater element.
• Check heater element.
• Replace the temperature probe.
• Replace the thermister.
• Replace the thermister.
• Clean the water level probes.
• The water temperature may be too high
– lower the temperature.
• Inlet valve may be leaking – replace inlet
valve.
• At this point, the water tank is not full
and this message has to be reset. To reset
it, switch the power off and on.
• If the problem persists, check all
components on the water line (water filter,
tubing, fittings, etc.).
• Check inlet valve to make certain it is
functioning properly.
• In the case of a temporary disruption
with the water supply, the coffee maker will
reset itself after every hour.
• The whipper motor may be jammed.
Clean the whipper assembly.
• Verify wiring to the whipper assembly.
• The whipper motor assembly may need
to be replaced.
Eccellenza Pod
33