Troubleshooting Suggestions - Wells DeLUXE Owner's Manual

Countertop food warmers & soup cookers
Hide thumbs Also See for DeLUXE:
Table of Contents

Advertisement

TROUBLE SHOOTING SUGGESTIONS
SYMPTOM
No power to warmer
Warmer will not heat
Warmer trips circuit breaker
Warmer slow to heat
POSSIBLE CAUSE
Circuit breaker off or tripped
Unit not plugged in
Temperature control not set
Internal damage
Wet insulation
Pan leaking or other internal
damage
Internal damage
Warmer used in "dry" mode
(inset) slow to heat; or, used "wet"
with insufficient water in well
(Deluxe)
Mineral deposits in well acting
as a insulator
(SC-7 and SC-11)
Mineral deposits in well acting
as a insulator
Connected to wrong voltage
Too much water in well
10
SUGGESTED REMEDY
Reset circuit breaker
Make sure unit is plugged in to
power receptacle
Set control to desired
temperature
Contact you Authorized Wells
Service Agency for repairs
Allow to dry or replace insulation
Contact your Authorized Wells
Service Agency for repairs
Contact your Authorized Wells
Service Agency for repairs
Warmer will heat the inset faster
when used in "wet" mode. Allow
to cool, then add 1" of water to
well
Clean well with delime cleaner.
DO NOT USE ON ALUMINUM
SURFACES!
Remove deposits with a plastic
scouring pad.
Verify supply voltage (must
match voltage on warmer
nameplate)
Remove water from pan until no
more than 1" of water remains in
well
There are no user-serviceable
components in this appliance.
In all instances of damage or
malfunction, contact your
Authorized Wells Service Agency
for repairs.