Alarm sounds and status beeps

Table 26: Alarm sounds
Alarm type
Alarm sound
Fire
Repeating series of three beeps
Police
Continuous tone
Auxiliary
Rapid beeps
Table 27: Beep sounds
Beep type
Beep sound
Exit delay
Two or three beeps (arming level), followed by one beep every 4 seconds,
followed by 10 seconds of quick beeps (end of exit delay), followed by two
or three beeps (set arming level).
Entry delay
Two beeps every 2 seconds, followed by two beeps every second for the
last 10 seconds.
Chime
Two beeps whenever a protected door or window is opened.
Chime on close
One long beep when a protected door or window is closed.
Protest
Repeating pattern of one long beep, followed by one short beep, followed by
one long beep.
Trouble
Five short beeps once every minute.
Sensor test
One short, high-pitched beep when a sensor/touchpad test okay. One short,
low-pitched beep when a sensor/touchpad fails a test (contact your dealer
for information or service). One short beep every minute during the last 5
minutes of the sensor test.