Installer Set Options

Key Fob Disarm After Alarm Sound

The system can be set so when it's disarmed with a wireless key fob after an alarm has occurred,
a special series of beeps will sound through the internal and external sounders. This option serves
as an alert to warn you to approach the premises with caution as an intruder may still be present.
★ IMPORTANT: I
f you return to the premises and hear the special beeps when disarming with the key fob, USE
CAUTION! The special beeps indicate that an alarm has occurred while you were gone. AN INTRUDER MAY
STILL BE ON THE PREMISES. LEAVE IMMEDIATELY AND CONTACT THE POLICE FROM A SAFE LOCATION.

Key Fob Options

The installer selects which options are enabled for each key fob (1-8) used with the system. Refer to
the table below for the options selected for your key fobs:
Option
Arm without Exit Delay
Allow key fob disarming
Enable key fob auxiliary key
KEY FOB EMERGENCY (AWAY & DISARM PRESSED) OPTIONS (Check one per fob)
Option
Auxiliary Alarm
Audible Alarm
Silent Panic Alarm
Fire Alarm
Emergency Keys Disabled
Auto-bypass all open perimeter sensors and un-bypass a sensor
if closed while the system is armed
Auto-bypass open perimeter sensors permanently while armed
Allow key fob arming only when all perimeter sensors are closed

Wireless Keypad Emergency Keys

Each standard wireless keypad has FIRE and POLICE emergency buttons that can be enabled or
disabled for each keypad. Refer to the table below for options set for your keypads:
Emergency Keys Enabled
Emergency Keys Disabled

Exit Delay Restart

The Exit Delay Restart option will extend the Exit Delay one time if you need to re-enter the premises.
When the system is armed in the Away Mode or Stay Mode, the Exit Delay gives you time to leave
without setting off the alarm. With the Exit Delay Restart option, re-entering the premises after you
have left, but before the Exit Delay timer expires, will restart the Exit Delay timer, giving you the
full length of time to leave again. The restart option only works once, each time the system is armed.
44
KEY FOB DISARM AFTER ALARM SOUND
❑ OFF (regular setting)
KEY FOB GENERAL OPTIONS
Fob #1 Fob #2 Fob #3 Fob #4 Fob #5 Fob #6 Fob #7 Fob #8
Fob #1 Fob #2 Fob #3 Fob #4 Fob #5 Fob #6 Fob #7 Fob #8
KEY FOB ARMING BYPASS OPTIONS
Option
STANDARD WIRELESS KEYPAD EMERGENCY KEYS
Option
EXIT DELAY RESTART
❑ ON (regular setting)
❑ ON
Keypad #1 Keypad #2 Keypad #3 Keypad #4
❑ OFF
All Key Fobs