Specifications - HearthStone Tucson 8702 ST Owner's Manual

Gas-fired direct-vent heater installation & operating instructions
Table of Contents

Advertisement

Hearthstone Quality Home Heating Products, Inc.
L
: Gas-Fired Direct-Vent Fireplace Heater
ISTED
Model: Tucson Direct-Vent Gas Fireplace
Heater (8702)
Testing Agency: Intertek Testing Services
NA, Inc. (ITS)
Tested to: ANSI Z21.88-2005, CSA 2.33b
2005, CAN/CGA2.17-M91
Certified for Canada, CSA P.4.1
Approved for Mobile Home Installation (see
page 7)
Specification
INPUT RATING (Btu/hr) 0-2000 ft
INPUT RATING (Btu/hr) 2000-4500 ft
ORIFICE SIZE (DMS) 0-2000 ft
ORIFICE SIZE (DMS) 2000-4500 ft
MANIFOLD PRESSURE - LO SETTING (in. W.c./kpa)
MANIFOLD PRESSURE - HI SETTING (in. W.c./kpa)
INLET PRESSURE - MINIMUM (in.w.c./kpa)
INLET PRESSURE – MAXIMUM (in. w.c./kpa)
MINIMUM INPUT RATING LO SETTING (btu/hr)
MAXIMUM OUTPUT (btu/hr) 0-2000 ft

Specifications

Certified for use by:
Board of State Examiners of Plumbers & Gasfitters
100 Cambridge Street, Room 1511
Boston, MA 02202
www.mass.gov
Figure 2: Model 8702 Dimensions
12
Tucson DX/ST Model 8702
NG
LP
25,000
25,000
24,200
24,800
41
53
42
54
1.6/0.4
6.4/1.59
3.5/0.87
10.0/2.48
5.0/1.24
12.0/2.99
7.0/1.74
13/3.22
18,000
21,600
17,350
19,100

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tucson 8702 dxTucson dxTucson st