C Group: Inverter - Vetus Combi-Gamma COMBI1512 Operation And Installation Instructions Manual

Inverter - battery charger
Table of Contents

Advertisement

B4-03: 2-3 Phase Type
Use setting B4-03 to determine the kind of multi-phase required.
Setting
B4-03=0
(Initial setting)
B4-03=1
B4-03=2
C Group (INVERTER):
C1 Group (INVERTER)
C1-01: INVERTER Output Voltage
Use constant C1-01 to change the RMS output voltage of the INVERTER.
C1-02: Bat Low - V Shut-down
With this setting, one can determine the battery voltage at which level the INVERTER will
switch off. This can be useful to prevent drawing too much current from an exhausted
battery.
This voltage level will always lie below the
changing this level will also change the Bat Low - V Restart (C1-03) level.
C1-03=C1-02+offset voltage
C1-03: Battery Low ? V Restart
This setting forms a pair with
termines the battery voltage at which level the INVERTER will switch on.
In fact, the parameter which is changed is the difference between Bat Low ? V Shut-
down (C1-02) and Bat Low ? V Restart (C1-03). The result of this is that when changing
the Bat Low ? V Shut-down (C1-02) level, this level also changes.
C1-05: Load Support Select
Using this constant C1-05, the
Load Support to prevent an external circuit breaker to trip when the load on the Combi-
Gamma is too high.
If the load exceeds the
ing and will provide the extra current needed.
*
Note: When Load Support is enabled. C1-05=1 (Initial setting), there is a minimum
AC input current limit of approximate 2-3 Amps. Setting a lower limit (B2-05) than this
60
090138.02
3 Phase type:
Three Combi-Gamma are required.
Output is 3-phase with a 120° phase shift.
Split Phase 180° type:
Two Combi-Gamma are required.
Output is 2-phase with a 180° phase shift
Two Leg 3 Phase 120° type:
Two Combi-Gamma are required.
Output is 2-phase of a normal 3-phase system (two phases with 120° phase shift).
Bat Low - V Shut-down (C1-02). With this setting, one de-
Load Support feature can be enabled or disabled. Use
AC IN Current Limit (B2-05), the Combi-Gamma will start invert-
Function
Bat Low - V Restart (C1-03) level. In fact,
Battery charger / inverter COMBI-GAMMA