1.4 Connection of Battery Cables

In order to fully utilize the full capacity of the product, batteries with sufficient capacity and
battery cables with sufficient cross section should be used, please see table:
Item
Recommended battery capacity (Ah)
Recommended cross section (0~6m)
Remark: Internal resistance is the important factor when working with low capacity batteries. Consult your supplier.
If the Combi is equipped with 2 DC connectors COMBI3012, connect both con-
nectors to the battery cables (2 x Red, 2 x Black).
Procedure:
Proceed as follows to connect the battery cables:
Avoid shorting the battery cables.
Crimp the uninsulated (+)and (-) connector to the battery cables.
Mount the connectors in the plastic cover.
Don't reverse the (+) and (-) in the cover. This may cause internal damage!
Put the complete connector on the contra connector in the box.
The enclosure must be grounded for safety purpose. An earth screw has been fitted at
the bottom side of the enclosure.

1.5 Connection of AC Cabling

The shore or the mains (AC IN) cable supplied with the unit must be connected to AC IN
connector at the bottom, use the supplied three-wire cable.
Proceed as follows to connect the AC cables.
The AC output cable can be connected directly to the blue CEE-form connector marked
"AC OUT". The corresponding connector for each different country must be connected
to the opposite side of the cable.
The current which is switched through to the output (AC OUT) is not fused. External
fuses or current limiters have to be installed.
Battery charger / inverter COMBI-GAMMA
Model
COMBI1512
200~700
50 mm
2
COMBI1524
COMBI3012
100~400
400~1200
50 mm
2
2 x 50 mm
COMBI3024
200~700
2
50 mm
2
11
090138.02

Advertisement

Table of Contents
loading

Table of Contents