Chapter 2 Settings; Four Control Modes Applicatioin; Mode 1: Ac Power As Priority Support - Vetus Combi-Gamma COMBI1512 Operation And Installation Instructions Manual

Inverter - battery charger
Table of Contents

Advertisement

2.1 Four Control Modes Applications

MODE 1: AC Power as Priority Support

1.
INVERTER Mode:
When AC IN=0 A, AC OUT load is completely supplied by INVERTER. It goes to the
inverter mode.
Grid,Shore,Generator
2.
Power Control Mode (a)
In this example:
All AC loads are off, with the "Combi-Gamma" constant B2-05=5A (AC IN Current Limit),
the AC CHARGER will not take more than 5A with limits to battery charge current to
75A.
14
090138.02

Chapter 2 Settings

Power
0A
AC IN
ATS OFF
5A
75A
Battery
Load
5A
AC OUT
Battery charger / inverter COMBI-GAMMA

Advertisement

Table of Contents
loading

Table of Contents