C
 
 FXO C
ONFIGURING
THE
Configuring the FXO channels on the GXW410x gateway is an easy process.  Follow the GUI interfaces. 
The  Device  Status  page  terms  are  defined  in  Table   9:   FXO  Lines   Configuration  Definitions.    An 
example of the Channel Dialing Configuration is shown in Figure 6.   Please note the default is always 
configured.  The user has the option to change the default settings as described in the Table 9.
T
 9:  FXO L
 C
ABLE
INES
Syntax for Channel Specific Settings:
Default: ch1­8:X; {all channels 1 to 8 are set to use value X}
Additional Examples:
 ch1,3­6:10;ch2,7­8:12 {channels 1,3,4,5 and 6 are set to use value 10 while channels 2,7 and 8 
are set to use value 12.
Enable Current 
When set to Y, Current Disconnect is enabled. Certain PSTN COs require this to be enabled, in 
order to realize disconnect signal from PSTN side.  Default is Y.
Disconnect
If enabled use threshold: Default is 100ms. Range is 40ms to 800ms.
Certain PSTN service providers have a threshold time within which the line stabilizes after off­
hook. It is entirely dependent on provider, however if you experience PSTN line detection issues, 
please modify this setting appropriately in 100ms increments.
If you are not sure if this option should be enabled please refer to Table 10 (FXO Lines Test Tab 
Definition). This tool will run an automated test to determine the proper PSTN configuration that 
the gateway should have to work with your Service Provider or analog PBX.
Enable Tone 
Default is No. If PSTN provider uses call progress tones then it should be set to Yes in order to 
realize disconnect tone. Please configure accurate Call Progress Tones on Channels web page 
Disconnect
based on PSTN provider (or traditional PBX) settings.
If you are not sure if this option should be enabled or what Call Progress Tones are required 
please refer to Table 10 (FXO Lines Test Tab Definition). This tool will run an automated test to 
determine the proper PSTN configuration that the gateway should have to work with your Service 
Provider or analog PBX.
Enable Polarity 
Default is No. This should be set to Yes only if the FXO lines are subscribed to PR service from 
PSTN Service provider. It is merely a PR detect feature.
Reversal
***Note:  If there is no PR service from provider on the FXO line, and this setting is configured to 
Yes, calls will not be successful.
Silence Timeout
Terminate call after long silence detected. Default is 60 seconds, max 65536.
AC Termination 
Selects the impedance of the analog line connected to the FXO port on the GXW410x. Here is 
some basic information which may be helpful for initial configuration:
Impedance
600 Ohm – North America;
270 Ohm + (750 Ohm || 150 nF) ­­ Most of Europe 
220 Ohm + (820 Ohm || 120 nF) – Australia, New Zealand
220 Ohm + (820 Ohm || 115 nF) – Austria, Bulgaria, Germany, Slovakia, South Africa
370 Ohm + (620 Ohm || 310 nF) – UK., India
If this parameter is not configured properly you may experience echo or noise in the line. Please 
refer   to   Table   10   (FXO   Lines   Test   Tab   Definition).   This   tool   will   run   an   automated   test   to 
determine the correct impedance value to match your lines. 
 