7
Electric system
154
155
156
157
- 64 -
Magnetization checking tool (Part No. 7000-9727-001)
Components:
1 Casing
2 Slider
3 Casing reference line
4 Slider reference line
Rest the tool end horizontally onto the magnetic poles.
Hold sfider so that its reference line coincides with the casing referen-
ce line.
Release slider: if no attraction occurs the rotor is demagnetized; the-
refore replace alternator.
Checking for cable continuity
Check that stator windings have no unsoldered connections, burnt
areas or grounded wires.
Using an ohmmeter check for continuity between the red cable and
the two yellow ones.
Furthermore, check that they are insulated from the ground.
Voltage regulator
Supplied by SAPRISA : Voltage 12 V, max. current 26A.
To avoid wrong connections 3 different sizes are supplied.
Ref.
~
R
+
LE
O O
KD Workshop Manual_cod. ED0053029350_1° ed_ rev. 00
Connection size (mm)
Width
Thickness
6.25
0.8
9.50
1.12
9.50
1.12
4.75
0.5
6.25
0.8