Magnetization Checking Tool (Part No. 7000-9727-001); Checking For Cable Continuity; Voltage Regulator - Kohler KD 625/3 Workshop Manual

Air cooled, direct injection
Hide thumbs Also See for KD 625/3:
Table of Contents

Advertisement

7
Electric system
154
155
156
157
- 64 -

Magnetization checking tool (Part No. 7000-9727-001)

Components:
1 Casing
2 Slider
3 Casing reference line
4 Slider reference line
Rest the tool end horizontally onto the magnetic poles.
Hold sfider so that its reference line coincides with the casing referen-
ce line.
Release slider: if no attraction occurs the rotor is demagnetized; the-
refore replace alternator.

Checking for cable continuity

Check that stator windings have no unsoldered connections, burnt
areas or grounded wires.
Using an ohmmeter check for continuity between the red cable and
the two yellow ones.
Furthermore, check that they are insulated from the ground.

Voltage regulator

Supplied by SAPRISA : Voltage 12 V, max. current 26A.
To avoid wrong connections 3 different sizes are supplied.
Ref.
~
R
+
LE
O O
KD Workshop Manual_cod. ED0053029350_1° ed_ rev. 00
Connection size (mm)
Width
Thickness
6.25
0.8
9.50
1.12
9.50
1.12
4.75
0.5
6.25
0.8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rd 626/3Kd 626/3

Table of Contents