7
ELECTRIC SYSTEM
147
148
- 66 -
Electric starting layout with internal alternator
Electrical starting layout with external alternator
KD 625-2 Workshop Manual_cod. ED0053029380_1° ed_ rev. 00
Components:
1 Alternator
2 Starting motor
3 Voltage regulator
4 Battery
5 Pressure switch
6 Oil pressure warning light
7 Key switch
8 Battery charging light
Note: Battery, which is not supplied by
Kohler, should feature 12 V voltage
and capacity not below 70 Ah.
Components:
1 Alternator
2 Starting motor
3 Battery
4 Key switch
5 Pressure switch
6 Oil pressure warning light
7 Battery charging light
Note: Battery, which is not supplied by
Kohler, should feature 12 V voltage
and capacity not below 70 Ah.