Valve Timing Check; Valve Timing - Angles; Hydraulic Pump; Hydraulic Pump P.t.o - Kohler KD 625/2 Workshop Manual

Air-cooled, direct injection
Hide thumbs Also See for KD 625/2:
Table of Contents

Advertisement

90
91
92
KD 625-2 Workshop Manual_cod. ED0053029380_1° ed_ rev. 00
Disassembly / Reassembly

Valve timing check

Check valve timing at the crankshaft.
The values shown are checked at the flywheel circumference (with
flywheel of 291 mm. diameter each degree corresponds to 2.5 mm).
Set valve clearance at 0.65÷0.70 mm (after checking restore the value
at 0.15÷0.20 mm).
Set dial gauge on intake valve to a zero value; by rotating the driving
shaft according to its direction of rotation you can measure α (intake
valve opening advance referred to top dead centre S) and ß (intake
valve closing delay referred to bottom (I) dead centre).
Follow the same procedure for exhaust valves checking γ (exhaust valve
opening advance) and δ (exhaust valve closing delay).

Valve timing - Angles

The angle values are determined by turning the driving shaft clockwi-
se
S = Piston at
top dead centre
I = Piston at bottom dead centre
α
= Intake valve open
β
= Intake valve closed
γ
= Exhaust valve open
δ
= Exhaust valve closed
Timing angles for checking puposes
(valve clearance = 0,65÷0,70 mm)
α
= 1° before S
β
= 21° after I
γ
= 23° before I
δ
= 1° after S

HYDRAULIC PUMP

Hydraulic pump p.t.o

A hydraulic pump of group 1 (1P) or 2 (2P) can be installed on the gear
side, 3rd p.t.o.
4
- 47 -